MWPowerPlantFacts

Data last collected:

EIA plant 10307

Bellingham · Norfolk · MA

Bellingham Cogeneration Facility

Operated by Northeast Energy Associates LP

Annual generation367,825 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextISO New England Inc.Balancing authority or NERC region

Published location

Where is Bellingham Cogeneration Facility?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

42.092500, -71.483300

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle386.1 MW represented

Grouped from this plant’s represented generator records. Use the MA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

10
20
30
4872
50
623,166
7162,217
8107,121
922
1027,642
1145,469
121,316

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
10
20
30
4872
50
623,166
7162,217
8107,121
922
1027,642
1145,469
121,316

2024 monthly net generation

MonthNet generation
10 MWh
20 MWh
30 MWh
4872 MWh
50 MWh
623,166 MWh
7162,217 MWh
8107,121 MWh
922 MWh
1027,642 MWh
1145,469 MWh
121,316 MWh

Operating generators

IDTechnologyFuelMWStatus
CT1Natural Gas Fired Combined CycleNG128.7OP
CT2Natural Gas Fired Combined CycleNG128.7OP
ST1Natural Gas Fired Combined CycleNG128.7OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
10307
Sector
IPP Non-CHP
Water source
Plant uses ACC
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Bellingham Cogeneration Facility power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Bellingham Cogeneration Facility

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (162,217 MWh) and 1, 2, 3, 5 the lowest (0 MWh). Their difference is 162,217 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CT1Natural Gas Fired Combined Cycle128.7102.0126.085.0
CT2Natural Gas Fired Combined Cycle128.7102.0126.085.0
ST1Natural Gas Fired Combined Cycle128.760.084.030.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check