MWPowerPlantFacts

Data last collected:

EIA plant 10603

Ebensburg · Cambria · PA

Ebensburg Power

Operated by Ebensburg Power Co

Annual generation357,827 MWhSum of represented EIA-923 rows
Fuel codesWCCodes retained from EIA records
Grid contextPJM Interconnection, LLCBalancing authority or NERC region

Published location

Where is Ebensburg Power?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

40.455000, -78.747200

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyConventional Steam Coal57.6 MW represented

Grouped from this plant’s represented generator records. Use the PA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

133,315
229,812
333,702
433,104
527,205
632,841
734,315
834,031
932,486
1011,704
1121,024
1234,288

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
133,315
229,812
333,702
433,104
527,205
632,841
734,315
834,031
932,486
1011,704
1121,024
1234,288

2024 monthly net generation

MonthNet generation
133,315 MWh
229,812 MWh
333,702 MWh
433,104 MWh
527,205 MWh
632,841 MWh
734,315 MWh
834,031 MWh
932,486 MWh
1011,704 MWh
1121,024 MWh
1234,288 MWh

Operating generators

IDTechnologyFuelMWStatus
GEN1Conventional Steam CoalWC57.6OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
10603
Sector
IPP Non-CHP
Water source
Wilmore Dam
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Ebensburg Power power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Ebensburg Power

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (34,315 MWh) and 10 the lowest (11,704 MWh). Their difference is 22,611 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
GEN1Conventional Steam Coal57.650.050.020.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.