MWPowerPlantFacts

Data last collected:

EIA plant 10699

Pennington · Choctaw · AL

Georgia-Pacific Consr Prods LP-Naheola

Operated by Georgia-Pacific Consr Prods LP-Naheola

Annual generation315,371 MWhSum of represented EIA-923 rows
Fuel codesBLQ, WDSCodes retained from EIA records
Grid contextSouthern Company Services, Inc. - TransBalancing authority or NERC region

Published location

Where is Georgia-Pacific Consr Prods LP-Naheola?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

32.226800, -88.025200

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyWood/Wood Waste Biomass87.5 MW represented

Grouped from this plant’s represented generator records. Use the AL plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

120,600
229,024
318,793
425,769
530,000.73
619,933
716,111
833,462.61
939,223.45
1011,182
1133,312.81
1237,959.7

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
120,600
229,024
318,793
425,769
530,000.73
619,933
716,111
833,462.61
939,223.45
1011,182
1133,312.81
1237,959.7

2024 monthly net generation

MonthNet generation
120,600 MWh
229,024 MWh
318,793 MWh
425,769 MWh
530,001 MWh
619,933 MWh
716,111 MWh
833,463 MWh
939,223 MWh
1011,182 MWh
1133,313 MWh
1237,960 MWh

Operating generators

IDTechnologyFuelMWStatus
GT3Wood/Wood Waste BiomassBLQ47.2OP
TG4Wood/Wood Waste BiomassWDS40.3OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
10699
Sector
Industrial CHP
Water source
Tombigbee River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Georgia-Pacific Consr Prods LP-Naheola power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Georgia-Pacific Consr Prods LP-Naheola

Variation in the published months

Across 12 numeric monthly generation entries, 9 has the highest recorded value (39,223 MWh) and 10 the lowest (11,182 MWh). Their difference is 28,041 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
GT3Wood/Wood Waste Biomass47.237.437.73.0
TG4Wood/Wood Waste Biomass40.329.429.72.6

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check