EIA plant 10745

Midland · Midland · MI

Midland Cogeneration Venture

Operated by Midland Cogeneration Venture

Annual generation10,766,051 MWhSum of represented EIA-923 rows
Fuel codesDFO, NGCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is Midland Cogeneration Venture?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

43.586100, -84.224200

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle1,848.6 MW represented
TechnologyPetroleum Liquids5.2 MW represented

Grouped from this plant’s represented generator records. Use the MI plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1886,233.71
2851,552.33
3864,779.25
4913,516.9
5979,954.14
6897,231.57
7991,305.08
8966,647.68
9868,575.83
10888,599.54
11884,600.23
12773,055.08

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1886,233.71
2851,552.33
3864,779.25
4913,516.9
5979,954.14
6897,231.57
7991,305.08
8966,647.68
9868,575.83
10888,599.54
11884,600.23
12773,055.08

2024 monthly net generation

MonthNet generation
1886,234 MWh
2851,552 MWh
3864,779 MWh
4913,517 MWh
5979,954 MWh
6897,232 MWh
7991,305 MWh
8966,648 MWh
9868,576 MWh
10888,600 MWh
11884,600 MWh
12773,055 MWh

Operating generators

IDTechnologyFuelMWStatus
ST1Natural Gas Fired Combined CycleNG410OP
ST2Natural Gas Fired Combined CycleNG380SB
GT10Natural Gas Fired Combined CycleNG87.1OP
GT11Natural Gas Fired Combined CycleNG87.1OP
GT12Natural Gas Fired Combined CycleNG87.1OP
GT13Natural Gas Fired Combined CycleNG87.1OP
GT14Natural Gas Fired Combined CycleNG87.1OP
GT3Natural Gas Fired Combined CycleNG87.1OP
GT4Natural Gas Fired Combined CycleNG87.1OP
GT5Natural Gas Fired Combined CycleNG87.1OP
GT6Natural Gas Fired Combined CycleNG87.1OP
GT7Natural Gas Fired Combined CycleNG87.1OP
GT8Natural Gas Fired Combined CycleNG87.1OP
GT9Natural Gas Fired Combined CycleNG87.1OP
BP15Natural Gas Fired Combined CycleNG13.4OP
1G12Petroleum LiquidsDFO5.2SB

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
10745
Sector
IPP CHP
Water source
Tittabawasse River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Midland Cogeneration Venture power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Midland Cogeneration Venture

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (991,305 MWh) and 12 the lowest (773,055 MWh). Their difference is 218,250 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 16 numeric rows displayed in this table, MW ranges from 5.2 (1G12) to 410 (ST1). The difference is 404.8 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1G12Petroleum Liquids5.25.25.21.0
BP15Natural Gas Fired Combined Cycle13.413.413.41.0
GT10Natural Gas Fired Combined Cycle87.188.0103.070.0
GT11Natural Gas Fired Combined Cycle87.188.0103.070.0
GT12Natural Gas Fired Combined Cycle87.188.0103.070.0
GT13Natural Gas Fired Combined Cycle87.188.0103.070.0
GT14Natural Gas Fired Combined Cycle87.188.0103.070.0
GT3Natural Gas Fired Combined Cycle87.188.0103.070.0
GT4Natural Gas Fired Combined Cycle87.188.0103.070.0
GT5Natural Gas Fired Combined Cycle87.188.0103.070.0
GT6Natural Gas Fired Combined Cycle87.188.0103.070.0
GT7Natural Gas Fired Combined Cycle87.188.0103.070.0
GT8Natural Gas Fired Combined Cycle87.188.0103.070.0
GT9Natural Gas Fired Combined Cycle87.188.0103.070.0
ST1Natural Gas Fired Combined Cycle410.0410.0410.025.0
ST2Natural Gas Fired Combined Cycle380.0380.0380.040.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.