MWPowerPlantFacts

Data last collected:

EIA plant 126

Tucson · Pima · AZ

H Wilson Sundt Generating Station

Operated by Tucson Electric Power Co

Annual generation1,805,541 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextTucson Electric Power CompanyBalancing authority or NERC region

Published location

Where is H Wilson Sundt Generating Station?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

32.160000, -110.904700

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Steam Turbine286.9 MW represented
TechnologyNatural Gas Internal Combustion Engine188 MW represented
TechnologyNatural Gas Fired Combustion Turbine54 MW represented

Grouped from this plant’s represented generator records. Use the AZ plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

155,060
253,277
365,338
4141,183
5175,152
6200,142
7244,636
8243,288
9190,728
10193,627
11140,566
12102,544

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
155,060
253,277
365,338
4141,183
5175,152
6200,142
7244,636
8243,288
9190,728
10193,627
11140,566
12102,544

2024 monthly net generation

MonthNet generation
155,060 MWh
253,277 MWh
365,338 MWh
4141,183 MWh
5175,152 MWh
6200,142 MWh
7244,636 MWh
8243,288 MWh
9190,728 MWh
10193,627 MWh
11140,566 MWh
12102,544 MWh

Operating generators

IDTechnologyFuelMWStatus
4Natural Gas Steam TurbineNG173.3OP
ST3Natural Gas Steam TurbineNG113.6OP
GT1Natural Gas Fired Combustion TurbineNG27OP
GT2Natural Gas Fired Combustion TurbineNG27OP
RIC1Natural Gas Internal Combustion EngineNG18.8OP
RIC10Natural Gas Internal Combustion EngineNG18.8OP
RIC2Natural Gas Internal Combustion EngineNG18.8OP
RIC3Natural Gas Internal Combustion EngineNG18.8OP
RIC4Natural Gas Internal Combustion EngineNG18.8OP
RIC5Natural Gas Internal Combustion EngineNG18.8OP
RIC6Natural Gas Internal Combustion EngineNG18.8OP
RIC7Natural Gas Internal Combustion EngineNG18.8OP
RIC8Natural Gas Internal Combustion EngineNG18.8OP
RIC9Natural Gas Internal Combustion EngineNG18.8OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
126
Sector
Electric Utility
Water source
Wells
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right H Wilson Sundt Generating Station power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at H Wilson Sundt Generating Station

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (244,636 MWh) and 2 the lowest (53,277 MWh). Their difference is 191,359 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 14 numeric rows displayed in this table, MW ranges from 18.8 (RIC1, RIC10, RIC2) to 173.3 (4). The difference is 154.5 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
4Natural Gas Steam Turbine173.3156.0156.026.0
GT1Natural Gas Fired Combustion Turbine27.024.026.85.0
GT2Natural Gas Fired Combustion Turbine27.024.026.85.0
RIC1Natural Gas Internal Combustion Engine18.818.218.74.7
RIC10Natural Gas Internal Combustion Engine18.818.218.74.7
RIC2Natural Gas Internal Combustion Engine18.818.218.74.7
RIC3Natural Gas Internal Combustion Engine18.818.218.74.7
RIC4Natural Gas Internal Combustion Engine18.818.218.74.7
RIC5Natural Gas Internal Combustion Engine18.818.218.74.7
RIC6Natural Gas Internal Combustion Engine18.818.218.74.7
RIC7Natural Gas Internal Combustion Engine18.818.218.74.7
RIC8Natural Gas Internal Combustion Engine18.818.218.74.7
RIC9Natural Gas Internal Combustion Engine18.818.218.74.7
ST3Natural Gas Steam Turbine113.6104.0104.025.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.