MWPowerPlantFacts

Data last collected:

EIA plant 1896

Little Falls · Morrison · MN

Little Falls (MN)

Operated by ALLETE, Inc.

Annual generation31,649 MWhSum of represented EIA-923 rows
Fuel codesWATCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is Little Falls (MN)?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

45.975013, -94.369094

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyConventional Hydroelectric4.6 MW represented

Grouped from this plant’s represented generator records. Use the MN plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

13,009
23,296
32,568
43,229
53,227
63,017
73,202
81,816
92,268
101,481
112,057
122,479

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
13,009
23,296
32,568
43,229
53,227
63,017
73,202
81,816
92,268
101,481
112,057
122,479

2024 monthly net generation

MonthNet generation
13,009 MWh
23,296 MWh
32,568 MWh
43,229 MWh
53,227 MWh
63,017 MWh
73,202 MWh
81,816 MWh
92,268 MWh
101,481 MWh
112,057 MWh
122,479 MWh

Operating generators

IDTechnologyFuelMWStatus
4Conventional HydroelectricWAT1.2OP
3Conventional HydroelectricWAT1OP
1Conventional HydroelectricWAT0.8OP
2Conventional HydroelectricWAT0.8OP
5Conventional HydroelectricWAT0.4OP
6Conventional HydroelectricWAT0.4OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
1896
Sector
Electric Utility
Water source
Mississippi River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Little Falls (MN) power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Little Falls (MN)

Variation in the published months

Across 12 numeric monthly generation entries, 2 has the highest recorded value (3,296 MWh) and 10 the lowest (1,481 MWh). Their difference is 1,815 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 6 numeric rows displayed in this table, MW ranges from 0.4 (5, 6) to 1.2 (4). The difference is 0.8 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Conventional Hydroelectric0.80.90.90.1
2Conventional Hydroelectric0.80.90.90.1
3Conventional Hydroelectric1.01.01.00.3
4Conventional Hydroelectric1.21.31.30.5
5Conventional Hydroelectric0.40.50.50.1
6Conventional Hydroelectric0.40.50.50.1

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research