MWPowerPlantFacts

Data last collected:

EIA plant 2393

Milford · Hunterdon · NJ

Gilbert

Operated by Gilbert Power, LLC

Annual generation54,750 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextPJM Interconnection, LLCBalancing authority or NERC region

Published location

Where is Gilbert?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

40.565833, -75.163889

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle351 MW represented
TechnologyNatural Gas Fired Combustion Turbine161 MW represented

Grouped from this plant’s represented generator records. Use the NJ plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1742.99
2353.96
3303.21
41,086.59
51,306.09
65,708.41
721,778.74
820,731.1
9674.72
101,049.31
11821.6
12193.27

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1742.99
2353.96
3303.21
41,086.59
51,306.09
65,708.41
721,778.74
820,731.1
9674.72
101,049.31
11821.6
12193.27

2024 monthly net generation

MonthNet generation
1743 MWh
2354 MWh
3303 MWh
41,087 MWh
51,306 MWh
65,708 MWh
721,779 MWh
820,731 MWh
9675 MWh
101,049 MWh
11822 MWh
12193 MWh

Operating generators

IDTechnologyFuelMWStatus
9Natural Gas Fired Combustion TurbineNG161OP
8Natural Gas Fired Combined CycleNG135OP
4Natural Gas Fired Combined CycleNG54OP
5Natural Gas Fired Combined CycleNG54OP
6Natural Gas Fired Combined CycleNG54OP
7Natural Gas Fired Combined CycleNG54OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
2393
Sector
IPP Non-CHP
Water source
Delaware River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Gilbert power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Gilbert

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (21,779 MWh) and 12 the lowest (193 MWh). Their difference is 21,586 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 6 numeric rows displayed in this table, MW ranges from 54 (4, 5, 6) to 161 (9). The difference is 107 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
4Natural Gas Fired Combined Cycle54.049.056.042.0
5Natural Gas Fired Combined Cycle54.053.056.042.0
6Natural Gas Fired Combined Cycle54.055.056.042.0
7Natural Gas Fired Combined Cycle54.055.556.042.0
8Natural Gas Fired Combined Cycle135.090.0104.037.0
9Natural Gas Fired Combustion Turbine161.0152.7167.0150.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check