MWPowerPlantFacts

Data last collected:

EIA plant 2828

Brillant · Jefferson · OH

Cardinal

Operated by Cardinal Operating Company

Annual generation9,497,125 MWhSum of represented EIA-923 rows
Fuel codesBITCodes retained from EIA records
Grid contextPJM Interconnection, LLCBalancing authority or NERC region

Published location

Where is Cardinal?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

40.252200, -80.648600

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyConventional Steam Coal1,880.4 MW represented

Grouped from this plant’s represented generator records. Use the OH plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

11,174,742.01
2884,598
3669,003
4408,544
5753,025
61,039,247.96
7946,970
8967,857.01
9579,160
10704,474.01
11711,850
12657,654

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
11,174,742.01
2884,598
3669,003
4408,544
5753,025
61,039,247.96
7946,970
8967,857.01
9579,160
10704,474.01
11711,850
12657,654

2024 monthly net generation

MonthNet generation
11,174,742 MWh
2884,598 MWh
3669,003 MWh
4408,544 MWh
5753,025 MWh
61,039,248 MWh
7946,970 MWh
8967,857 MWh
9579,160 MWh
10704,474 MWh
11711,850 MWh
12657,654 MWh

Operating generators

IDTechnologyFuelMWStatus
3Conventional Steam CoalBIT650OP
1Conventional Steam CoalBIT615.2OP
2Conventional Steam CoalBIT615.2OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
2828
Sector
IPP Non-CHP
Water source
Ohio River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Cardinal power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Cardinal

Variation in the published months

Across 12 numeric monthly generation entries, 1 has the highest recorded value (1,174,742 MWh) and 4 the lowest (408,544 MWh). Their difference is 766,198 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 615.2 (1, 2) to 650 (3). The difference is 34.8 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Conventional Steam Coal615.2585.0595.0340.0
2Conventional Steam Coal615.2585.0595.0340.0
3Conventional Steam Coal650.0620.0620.0400.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check