MWPowerPlantFacts

Data last collected:

EIA plant 3779

Lynchburg · Campbell · VA

Reusens

Operated by Eagle Creek Renewable Energy, LLC

Annual generation18,538 MWhSum of represented EIA-923 rows
Fuel codesWATCodes retained from EIA records
Grid contextPJM Interconnection, LLCBalancing authority or NERC region

Published location

Where is Reusens?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

37.463900, -79.185600

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyConventional Hydroelectric12.5 MW represented

Grouped from this plant’s represented generator records. Use the VA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

12,453
22,819
33,037
42,516
51,250
6705
7555
8961
9739
101,266
11593
121,644

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
12,453
22,819
33,037
42,516
51,250
6705
7555
8961
9739
101,266
11593
121,644

2024 monthly net generation

MonthNet generation
12,453 MWh
22,819 MWh
33,037 MWh
42,516 MWh
51,250 MWh
6705 MWh
7555 MWh
8961 MWh
9739 MWh
101,266 MWh
11593 MWh
121,644 MWh

Operating generators

IDTechnologyFuelMWStatus
1Conventional HydroelectricWAT2.5OP
2Conventional HydroelectricWAT2.5OP
3Conventional HydroelectricWAT2.5OP
4Conventional HydroelectricWAT2.5OS
5Conventional HydroelectricWAT2.5OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
3779
Sector
IPP Non-CHP
Water source
James River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Reusens power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Reusens

Variation in the published months

Across 12 numeric monthly generation entries, 3 has the highest recorded value (3,037 MWh) and 7 the lowest (555 MWh). Their difference is 2,482 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Conventional Hydroelectric2.52.52.51.0
2Conventional Hydroelectric2.52.52.51.0
3Conventional Hydroelectric2.52.52.51.0
4Conventional Hydroelectric2.52.52.51.0
5Conventional Hydroelectric2.52.52.51.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.