MWPowerPlantFacts

Data last collected:

EIA plant 4937

Horseshoe Bay · Llano · TX

Thomas C Ferguson

Operated by Lower Colorado River Authority

Annual generation3,612,457 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextElectric Reliability Council of Texas, Inc.Balancing authority or NERC region

Published location

Where is Thomas C Ferguson?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

30.558000, -98.372100

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle574.6 MW represented

Grouped from this plant’s represented generator records. Use the TX plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1291,769
2255,408
3318,435
484,211
5308,696
6361,712
7363,534
8364,476
9345,338
10239,481
11359,274
12320,123

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1291,769
2255,408
3318,435
484,211
5308,696
6361,712
7363,534
8364,476
9345,338
10239,481
11359,274
12320,123

2024 monthly net generation

MonthNet generation
1291,769 MWh
2255,408 MWh
3318,435 MWh
484,211 MWh
5308,696 MWh
6361,712 MWh
7363,534 MWh
8364,476 MWh
9345,338 MWh
10239,481 MWh
11359,274 MWh
12320,123 MWh

Operating generators

IDTechnologyFuelMWStatus
STGNatural Gas Fired Combined CycleNG204OP
CT-1Natural Gas Fired Combined CycleNG185.3OP
CT-2Natural Gas Fired Combined CycleNG185.3OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
4937
Sector
Electric Utility
Water source
Lake Lyndon B. Johnson
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Thomas C Ferguson power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Thomas C Ferguson

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (364,476 MWh) and 4 the lowest (84,211 MWh). Their difference is 280,265 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 185.3 (CT-1, CT-2) to 204 (STG). The difference is 18.7 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CT-1Natural Gas Fired Combined Cycle185.3168.0181.095.0
CT-2Natural Gas Fired Combined Cycle185.3168.0181.095.0
STGNatural Gas Fired Combined Cycle204.0180.0194.075.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research