MWPowerPlantFacts

Data last collected:

EIA plant 50152

Taft · St Charles · LA

Dow St Charles Operations

Operated by Dow Chemical Co - St Charles

Annual generation1,889,314 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is Dow St Charles Operations?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

29.986100, -90.441400

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle323.6 MW represented

Grouped from this plant’s represented generator records. Use the LA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1152,607
2165,344
3123,409
4157,499
5167,873
6149,364
7131,145
8165,203
9163,669
10152,930
11175,597
12184,674

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1152,607
2165,344
3123,409
4157,499
5167,873
6149,364
7131,145
8165,203
9163,669
10152,930
11175,597
12184,674

2024 monthly net generation

MonthNet generation
1152,607 MWh
2165,344 MWh
3123,409 MWh
4157,499 MWh
5167,873 MWh
6149,364 MWh
7131,145 MWh
8165,203 MWh
9163,669 MWh
10152,930 MWh
11175,597 MWh
12184,674 MWh

Operating generators

IDTechnologyFuelMWStatus
CGN1Natural Gas Fired Combined CycleNG125.8OP
CGN2Natural Gas Fired Combined CycleNG125.8OP
CSTGNatural Gas Fired Combined CycleNG50OP
STGNatural Gas Fired Combined CycleNG22OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
50152
Sector
Industrial CHP
Water source
Mississippi River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Dow St Charles Operations power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Dow St Charles Operations

Variation in the published months

Across 12 numeric monthly generation entries, 12 has the highest recorded value (184,674 MWh) and 3 the lowest (123,409 MWh). Their difference is 61,265 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 4 numeric rows displayed in this table, MW ranges from 22 (STG) to 125.8 (CGN1, CGN2). The difference is 103.8 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CGN1Natural Gas Fired Combined Cycle125.8100.0116.060.0
CGN2Natural Gas Fired Combined Cycle125.8100.0116.060.0
CSTGNatural Gas Fired Combined Cycle50.050.050.015.0
STGNatural Gas Fired Combined Cycle22.020.020.05.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check