MWPowerPlantFacts

Data last collected:

EIA plant 50312

Suncook · Merrimack · NH

Pembroke Hydro

Operated by Eagle Creek Renewable Energy, LLC

Annual generation7,402 MWhSum of represented EIA-923 rows
Fuel codesWATCodes retained from EIA records
Grid contextISO New England Inc.Balancing authority or NERC region

Published location

Where is Pembroke Hydro?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

43.130362, -71.453632

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyConventional Hydroelectric2.7 MW represented

Grouped from this plant’s represented generator records. Use the NH plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

11,222
21,152
31,658
41,518
5571
628
70
8283
90
10164
11191
12615

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
11,222
21,152
31,658
41,518
5571
628
70
8283
90
10164
11191
12615

2024 monthly net generation

MonthNet generation
11,222 MWh
21,152 MWh
31,658 MWh
41,518 MWh
5571 MWh
628 MWh
70 MWh
8283 MWh
90 MWh
10164 MWh
11191 MWh
12615 MWh

Operating generators

IDTechnologyFuelMWStatus
1Conventional HydroelectricWAT2.7OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
50312
Sector
IPP Non-CHP
Water source
Sun Cook River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Pembroke Hydro power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Pembroke Hydro

Variation in the published months

Across 12 numeric monthly generation entries, 3 has the highest recorded value (1,658 MWh) and 7, 9 the lowest (0 MWh). Their difference is 1,658 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Conventional Hydroelectric2.70.61.20.2

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check