MWPowerPlantFacts

Data last collected:

EIA plant 50481

Kingsport · Sullivan · TN

Tennessee Eastman Operations

Operated by Eastman Chemical Co-TN Ops

Annual generation1,144,432 MWhSum of represented EIA-923 rows
Fuel codesBIT, NGCodes retained from EIA records
Grid contextPJM Interconnection, LLCBalancing authority or NERC region

Published location

Where is Tennessee Eastman Operations?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

36.521900, -82.543100

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyConventional Steam Coal110.5 MW represented
TechnologyNatural Gas Steam Turbine83.8 MW represented

Grouped from this plant’s represented generator records. Use the TN plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

194,959
291,803
397,472
489,519
597,794
6100,015
7102,800
8102,843
988,392
1083,518
1197,843
1297,474

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
194,959
291,803
397,472
489,519
597,794
6100,015
7102,800
8102,843
988,392
1083,518
1197,843
1297,474

2024 monthly net generation

MonthNet generation
194,959 MWh
291,803 MWh
397,472 MWh
489,519 MWh
597,794 MWh
6100,015 MWh
7102,800 MWh
8102,843 MWh
988,392 MWh
1083,518 MWh
1197,843 MWh
1297,474 MWh

Operating generators

IDTechnologyFuelMWStatus
TG25Conventional Steam CoalBIT18OP
TG24Natural Gas Steam TurbineNG16.8OP
TG26Conventional Steam CoalBIT16.6OP
TG22Conventional Steam CoalBIT15.4OP
TG21Natural Gas Steam TurbineNG15OP
TG16Natural Gas Steam TurbineNG10.4OP
TG17Natural Gas Steam TurbineNG10.4OP
TG18Natural Gas Steam TurbineNG10.4OP
TG19Natural Gas Steam TurbineNG10.4OP
TG20Natural Gas Steam TurbineNG10.4OP
TG14Conventional Steam CoalBIT10OP
TG15Conventional Steam CoalBIT7.5OP
TG13Conventional Steam CoalBIT7OP
TG10Conventional Steam CoalBIT6OP
TG11Conventional Steam CoalBIT6OP
TG12Conventional Steam CoalBIT6OP
TGO7Conventional Steam CoalBIT6OP
TGO8Conventional Steam CoalBIT6OP
TGO9Conventional Steam CoalBIT6OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
50481
Sector
Industrial CHP
Water source
South Fork - Holston River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Tennessee Eastman Operations power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Tennessee Eastman Operations

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (102,843 MWh) and 10 the lowest (83,518 MWh). Their difference is 19,325 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 19 numeric rows displayed in this table, MW ranges from 6 (TG10, TG11, TG12) to 18 (TG25). The difference is 12 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
TG10Conventional Steam Coal6.06.06.02.0
TG11Conventional Steam Coal6.06.06.02.0
TG12Conventional Steam Coal6.06.06.02.0
TG13Conventional Steam Coal7.07.07.02.0
TG14Conventional Steam Coal10.010.010.02.0
TG15Conventional Steam Coal7.57.57.52.0
TG16Natural Gas Steam Turbine10.410.410.41.5
TG17Natural Gas Steam Turbine10.410.410.41.5
TG18Natural Gas Steam Turbine10.410.410.41.5
TG19Natural Gas Steam Turbine10.410.410.41.5
TG20Natural Gas Steam Turbine10.410.410.41.5
TG21Natural Gas Steam Turbine15.015.015.02.0
TG22Conventional Steam Coal15.415.415.41.5
TG24Natural Gas Steam Turbine16.816.816.82.0
TG25Conventional Steam Coal18.018.018.02.0
TG26Conventional Steam Coal16.616.616.61.5
TGO7Conventional Steam Coal6.06.06.02.0
TGO8Conventional Steam Coal6.06.06.02.0
TGO9Conventional Steam Coal6.06.06.02.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check