MWPowerPlantFacts

Data last collected:

EIA plant 50648

Bristol · Hartford · CT

Covanta Bristol Energy

Operated by Covanta Bristol Inc

Annual generation109,052 MWhSum of represented EIA-923 rows
Fuel codesMSWCodes retained from EIA records
Grid contextISO New England Inc.Balancing authority or NERC region

Published location

Where is Covanta Bristol Energy?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

41.649200, -72.915300

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyMunicipal Solid Waste16.3 MW represented

Grouped from this plant’s represented generator records. Use the CT plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

19,498
29,091
37,925
49,384
59,644
67,402
79,806
89,444
99,157
109,220
119,599
128,882

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
19,498
29,091
37,925
49,384
59,644
67,402
79,806
89,444
99,157
109,220
119,599
128,882

2024 monthly net generation

MonthNet generation
19,498 MWh
29,091 MWh
37,925 MWh
49,384 MWh
59,644 MWh
67,402 MWh
79,806 MWh
89,444 MWh
99,157 MWh
109,220 MWh
119,599 MWh
128,882 MWh

Operating generators

IDTechnologyFuelMWStatus
GEN1Municipal Solid WasteMSW16.3OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
50648
Sector
IPP Non-CHP
Water source
Municipality
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Covanta Bristol Energy power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Covanta Bristol Energy

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (9,806 MWh) and 6 the lowest (7,402 MWh). Their difference is 2,404 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
GEN1Municipal Solid Waste16.313.213.20.5

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check