MWPowerPlantFacts

Data last collected:

EIA plant 52176

Big Spring · Howard · TX

C R Wing Cogen Plant

Operated by BHER Power Resources, Inc

Annual generation133,743 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextElectric Reliability Council of Texas, Inc.Balancing authority or NERC region

Published location

Where is C R Wing Cogen Plant?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

32.273178, -101.422386

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle230 MW represented

Grouped from this plant’s represented generator records. Use the TX plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

13,927
22,865
32,763
40
50
61,123
79,067
829,609
914,820
1027,805
1122,681
1219,083

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
13,927
22,865
32,763
40
50
61,123
79,067
829,609
914,820
1027,805
1122,681
1219,083

2024 monthly net generation

MonthNet generation
13,927 MWh
22,865 MWh
32,763 MWh
40 MWh
50 MWh
61,123 MWh
79,067 MWh
829,609 MWh
914,820 MWh
1027,805 MWh
1122,681 MWh
1219,083 MWh

Operating generators

IDTechnologyFuelMWStatus
GEN1Natural Gas Fired Combined CycleNG77.5OP
GEN2Natural Gas Fired Combined CycleNG77.5OP
GEN3Natural Gas Fired Combined CycleNG75OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
52176
Sector
IPP CHP
Water source
Colo.River Municipal Water Dis
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right C R Wing Cogen Plant power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at C R Wing Cogen Plant

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (29,609 MWh) and 4, 5 the lowest (0 MWh). Their difference is 29,609 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 75 (GEN3) to 77.5 (GEN1, GEN2). The difference is 2.5 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
GEN1Natural Gas Fired Combined Cycle77.571.071.045.0
GEN2Natural Gas Fired Combined Cycle77.571.071.045.0
GEN3Natural Gas Fired Combined Cycle75.070.070.040.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check