MWPowerPlantFacts

Data last collected:

EIA plant 55089

Hahnville · St Charles · LA

Taft Cogeneration Facility

Operated by Occidental Chemical Corporation

Annual generation4,918,624 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is Taft Cogeneration Facility?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

29.988800, -90.459900

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle894.2 MW represented

Grouped from this plant’s represented generator records. Use the LA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1533,312
2509,835.01
3537,570
4518,906
5510,256
6480,014.01
7500,936
8509,271
9489,426
10140,144
1190,421
1298,533

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1533,312
2509,835.01
3537,570
4518,906
5510,256
6480,014.01
7500,936
8509,271
9489,426
10140,144
1190,421
1298,533

2024 monthly net generation

MonthNet generation
1533,312 MWh
2509,835 MWh
3537,570 MWh
4518,906 MWh
5510,256 MWh
6480,014 MWh
7500,936 MWh
8509,271 MWh
9489,426 MWh
10140,144 MWh
1190,421 MWh
1298,533 MWh

Operating generators

IDTechnologyFuelMWStatus
ST1Natural Gas Fired Combined CycleNG358.7OP
CT1Natural Gas Fired Combined CycleNG178.5OP
CT2Natural Gas Fired Combined CycleNG178.5OP
CT3Natural Gas Fired Combined CycleNG178.5OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
55089
Sector
Industrial CHP
Water source
Mississippi River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Taft Cogeneration Facility power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Taft Cogeneration Facility

Variation in the published months

Across 12 numeric monthly generation entries, 3 has the highest recorded value (537,570 MWh) and 11 the lowest (90,421 MWh). Their difference is 447,149 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 4 numeric rows displayed in this table, MW ranges from 178.5 (CT1, CT2, CT3) to 358.7 (ST1). The difference is 180.2 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CT1Natural Gas Fired Combined Cycle178.5146.6178.960.0
CT2Natural Gas Fired Combined Cycle178.5142.9176.260.0
CT3Natural Gas Fired Combined Cycle178.5150.3187.260.0
ST1Natural Gas Fired Combined Cycle358.7299.1323.575.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check