MWPowerPlantFacts

Data last collected:

EIA plant 55117

Lake Charles · Calcasieu · LA

RS Cogen

Operated by Westlake 2 US LLC

Annual generation2,042,544 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is RS Cogen?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

30.221000, -93.282600

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle493 MW represented

Grouped from this plant’s represented generator records. Use the LA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1297,544.59
2199,683.23
3111,043.66
4151,990.27
5163,398.44
6137,418.93
7154,237.76
8136,197.7
996,726.46
10145,823.01
11221,936
12226,543.5

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1297,544.59
2199,683.23
3111,043.66
4151,990.27
5163,398.44
6137,418.93
7154,237.76
8136,197.7
996,726.46
10145,823.01
11221,936
12226,543.5

2024 monthly net generation

MonthNet generation
1297,545 MWh
2199,683 MWh
3111,044 MWh
4151,990 MWh
5163,398 MWh
6137,419 MWh
7154,238 MWh
8136,198 MWh
996,726 MWh
10145,823 MWh
11221,936 MWh
12226,544 MWh

Operating generators

IDTechnologyFuelMWStatus
RS-5Natural Gas Fired Combined CycleNG195OP
RS-6Natural Gas Fired Combined CycleNG195OP
RS-4Natural Gas Fired Combined CycleNG103OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
55117
Sector
Industrial CHP
Water source
Sabine River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right RS Cogen power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at RS Cogen

Variation in the published months

Across 12 numeric monthly generation entries, 1 has the highest recorded value (297,545 MWh) and 9 the lowest (96,726 MWh). Their difference is 200,819 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 103 (RS-4) to 195 (RS-5, RS-6). The difference is 92 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
RS-4Natural Gas Fired Combined Cycle103.080.080.020.0
RS-5Natural Gas Fired Combined Cycle195.0167.7183.3100.0
RS-6Natural Gas Fired Combined Cycle195.0167.7183.3100.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.