MWPowerPlantFacts

Data last collected:

EIA plant 55139

Granbury · Hood · TX

Wolf Hollow I LP

Operated by Wolf Hollow I Power, LLC

Annual generation3,210,123 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextElectric Reliability Council of Texas, Inc.Balancing authority or NERC region

Published location

Where is Wolf Hollow I LP?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

32.334220, -97.731686

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle788.4 MW represented

Grouped from this plant’s represented generator records. Use the TX plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1268,980
2100,578
3286,366
48,714
5254,436
6314,463
7427,131
8482,855
9452,566
10310,262
11205,950
1297,822

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1268,980
2100,578
3286,366
48,714
5254,436
6314,463
7427,131
8482,855
9452,566
10310,262
11205,950
1297,822

2024 monthly net generation

MonthNet generation
1268,980 MWh
2100,578 MWh
3286,366 MWh
48,714 MWh
5254,436 MWh
6314,463 MWh
7427,131 MWh
8482,855 MWh
9452,566 MWh
10310,262 MWh
11205,950 MWh
1297,822 MWh

Operating generators

IDTechnologyFuelMWStatus
STNatural Gas Fired Combined CycleNG300.6OP
CTG1Natural Gas Fired Combined CycleNG243.9OP
CTG2Natural Gas Fired Combined CycleNG243.9OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
55139
Sector
IPP Non-CHP
Water source
Lake Granbury
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Wolf Hollow I LP power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Wolf Hollow I LP

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (482,855 MWh) and 4 the lowest (8,714 MWh). Their difference is 474,141 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 243.9 (CTG1, CTG2) to 300.6 (ST). The difference is 56.7 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CTG1Natural Gas Fired Combined Cycle243.9245.0255.094.0
CTG2Natural Gas Fired Combined Cycle243.9240.0247.094.0
STNatural Gas Fired Combined Cycle300.6271.0273.044.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.