MWPowerPlantFacts

Data last collected:

EIA plant 55153

Marion · Guadalupe · TX

Guadalupe Generating Station

Operated by Guadalupe Power Partners LP

Annual generation6,450,394 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextElectric Reliability Council of Texas, Inc.Balancing authority or NERC region

Published location

Where is Guadalupe Generating Station?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

29.624400, -98.141900

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle1,088.2 MW represented

Grouped from this plant’s represented generator records. Use the TX plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1600,950
2470,239
3577,618
4428,796
5638,703
6669,830
7715,991
8723,493
9680,735
10397,708
11221,737
12324,594

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1600,950
2470,239
3577,618
4428,796
5638,703
6669,830
7715,991
8723,493
9680,735
10397,708
11221,737
12324,594

2024 monthly net generation

MonthNet generation
1600,950 MWh
2470,239 MWh
3577,618 MWh
4428,796 MWh
5638,703 MWh
6669,830 MWh
7715,991 MWh
8723,493 MWh
9680,735 MWh
10397,708 MWh
11221,737 MWh
12324,594 MWh

Operating generators

IDTechnologyFuelMWStatus
STG1Natural Gas Fired Combined CycleNG201.9OP
STG2Natural Gas Fired Combined CycleNG201.9OP
CTG1Natural Gas Fired Combined CycleNG171.1OP
CTG2Natural Gas Fired Combined CycleNG171.1OP
CTG3Natural Gas Fired Combined CycleNG171.1OP
CTG4Natural Gas Fired Combined CycleNG171.1OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
55153
Sector
IPP Non-CHP
Water source
Lake Dunlap
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Guadalupe Generating Station power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Guadalupe Generating Station

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (723,493 MWh) and 11 the lowest (221,737 MWh). Their difference is 501,756 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 6 numeric rows displayed in this table, MW ranges from 171.1 (CTG1, CTG2, CTG3) to 201.9 (STG1, STG2). The difference is 30.8 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CTG1Natural Gas Fired Combined Cycle171.1153.0161.0100.0
CTG2Natural Gas Fired Combined Cycle171.1153.0161.0100.0
CTG3Natural Gas Fired Combined Cycle171.1153.0160.0100.0
CTG4Natural Gas Fired Combined Cycle171.1153.0160.0100.0
STG1Natural Gas Fired Combined Cycle201.9196.0200.0138.5
STG2Natural Gas Fired Combined Cycle201.9197.0200.0138.8

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check