MWPowerPlantFacts

Data last collected:

EIA plant 55170

Londonderry · Rockingham · NH

Granite Ridge

Operated by Granite Ridge Energy LLC

Annual generation3,137,690 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextISO New England Inc.Balancing authority or NERC region

Published location

Where is Granite Ridge?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

42.904200, -71.426100

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle790 MW represented

Grouped from this plant’s represented generator records. Use the NH plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1354,018
2191,941
3229,880
4231,843
5273,974
6384,670
738,962
8439,488
9420,931
10395,259
110
12176,724

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1354,018
2191,941
3229,880
4231,843
5273,974
6384,670
738,962
8439,488
9420,931
10395,259
110
12176,724

2024 monthly net generation

MonthNet generation
1354,018 MWh
2191,941 MWh
3229,880 MWh
4231,843 MWh
5273,974 MWh
6384,670 MWh
738,962 MWh
8439,488 MWh
9420,931 MWh
10395,259 MWh
110 MWh
12176,724 MWh

Operating generators

IDTechnologyFuelMWStatus
STGNatural Gas Fired Combined CycleNG270OP
CT11Natural Gas Fired Combined CycleNG260OP
CT12Natural Gas Fired Combined CycleNG260OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
55170
Sector
IPP Non-CHP
Water source
City of Manchester POTW
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Granite Ridge power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Granite Ridge

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (439,488 MWh) and 11 the lowest (0 MWh). Their difference is 439,488 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 260 (CT11, CT12) to 270 (STG). The difference is 10 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CT11Natural Gas Fired Combined Cycle260.0218.0243.0111.0
CT12Natural Gas Fired Combined Cycle260.0218.0243.0111.0
STGNatural Gas Fired Combined Cycle270.0232.0243.085.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.