MWPowerPlantFacts

Data last collected:

EIA plant 55173

Eunice · Acadia · LA

Acadia Energy Center

Operated by Cleco Power LLC

Annual generation5,787,348 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is Acadia Energy Center?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

30.428611, -92.413056

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle1,389.2 MW represented

Grouped from this plant’s represented generator records. Use the LA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1568,425
2361,409
3679,894
4275,945
5298,504
6573,661
7655,473
9638,747
10676,093
11542,092
12517,105

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 11 of 11 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1568,425
2361,409
3679,894
4275,945
5298,504
6573,661
7655,473
9638,747
10676,093
11542,092
12517,105

2024 monthly net generation

MonthNet generation
1568,425 MWh
2361,409 MWh
3679,894 MWh
4275,945 MWh
5298,504 MWh
6573,661 MWh
7655,473 MWh
9638,747 MWh
10676,093 MWh
11542,092 MWh
12517,105 MWh

Operating generators

IDTechnologyFuelMWStatus
ST13Natural Gas Fired Combined CycleNG264.4OP
ST26Natural Gas Fired Combined CycleNG264.4OP
CT11Natural Gas Fired Combined CycleNG215.1OP
CT12Natural Gas Fired Combined CycleNG215.1OP
CT24Natural Gas Fired Combined CycleNG215.1OP
CT25Natural Gas Fired Combined CycleNG215.1OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
55173
Sector
Electric Utility
Water source
Wells
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Acadia Energy Center power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Acadia Energy Center

Variation in the published months

Across 11 numeric monthly generation entries, 3 has the highest recorded value (679,894 MWh) and 4 the lowest (275,945 MWh). Their difference is 403,949 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 6 numeric rows displayed in this table, MW ranges from 215.1 (CT11, CT12, CT24) to 264.4 (ST13, ST26). The difference is 49.3 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CT11Natural Gas Fired Combined Cycle215.1168.3Not supplied105.2
CT12Natural Gas Fired Combined Cycle215.1166.0Not supplied105.2
CT24Natural Gas Fired Combined Cycle215.1145.5157.2105.2
CT25Natural Gas Fired Combined Cycle215.1145.0156.6105.2
ST13Natural Gas Fired Combined Cycle264.4203.8Not supplied72.0
ST26Natural Gas Fired Combined Cycle264.4235.9235.972.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.