MWPowerPlantFacts

Data last collected:

EIA plant 55418

Malvern · Hot Spring · AR

Hot Spring Generating Facility

Operated by Entergy Arkansas LLC

Annual generation2,034,559 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is Hot Spring Generating Facility?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

34.297590, -92.868344

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle714.8 MW represented

Grouped from this plant’s represented generator records. Use the AR plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

133
2282
395,960
493,962
5342,315
6177,062
7328,204
8320,969
9165,274
10273,781
11119,108
12117,609

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
133
2282
395,960
493,962
5342,315
6177,062
7328,204
8320,969
9165,274
10273,781
11119,108
12117,609

2024 monthly net generation

MonthNet generation
133 MWh
2282 MWh
395,960 MWh
493,962 MWh
5342,315 MWh
6177,062 MWh
7328,204 MWh
8320,969 MWh
9165,274 MWh
10273,781 MWh
11119,108 MWh
12117,609 MWh

Operating generators

IDTechnologyFuelMWStatus
ST1Natural Gas Fired Combined CycleNG317OP
CT1Natural Gas Fired Combined CycleNG198.9OP
CT2Natural Gas Fired Combined CycleNG198.9OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
55418
Sector
Electric Utility
Water source
Ouachita River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Hot Spring Generating Facility power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Hot Spring Generating Facility

Variation in the published months

Across 12 numeric monthly generation entries, 5 has the highest recorded value (342,315 MWh) and 1 the lowest (33 MWh). Their difference is 342,282 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 198.9 (CT1, CT2) to 317 (ST1). The difference is 118.1 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CT1Natural Gas Fired Combined Cycle198.9Not suppliedNot supplied80.0
CT2Natural Gas Fired Combined Cycle198.9Not suppliedNot supplied80.0
ST1Natural Gas Fired Combined Cycle317.0562.7636.235.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check