MWPowerPlantFacts

Data last collected:

EIA plant 56185

Chowchilla · Madera · CA

Chowchilla II

Operated by California Power Holdings LLC

Annual generation16,491 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextCalifornia Independent System OperatorBalancing authority or NERC region

Published location

Where is Chowchilla II?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

37.107300, -120.248500

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Internal Combustion Engine49.6 MW represented

Grouped from this plant’s represented generator records. Use the CA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

11,877.14
21,273.3
3911.39
4775.83
5698.06
61,073.95
72,063.28
81,792.17
91,578.57
101,653.87
111,331.8
121,461.63

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
11,877.14
21,273.3
3911.39
4775.83
5698.06
61,073.95
72,063.28
81,792.17
91,578.57
101,653.87
111,331.8
121,461.63

2024 monthly net generation

MonthNet generation
11,877 MWh
21,273 MWh
3911 MWh
4776 MWh
5698 MWh
61,074 MWh
72,063 MWh
81,792 MWh
91,579 MWh
101,654 MWh
111,332 MWh
121,462 MWh

Operating generators

IDTechnologyFuelMWStatus
IC1Natural Gas Internal Combustion EngineNG3.1OP
IC10Natural Gas Internal Combustion EngineNG3.1OP
IC11Natural Gas Internal Combustion EngineNG3.1OP
IC12Natural Gas Internal Combustion EngineNG3.1OP
IC13Natural Gas Internal Combustion EngineNG3.1OP
IC14Natural Gas Internal Combustion EngineNG3.1OP
IC15Natural Gas Internal Combustion EngineNG3.1OP
IC16Natural Gas Internal Combustion EngineNG3.1OP
IC2Natural Gas Internal Combustion EngineNG3.1OP
IC3Natural Gas Internal Combustion EngineNG3.1OP
IC4Natural Gas Internal Combustion EngineNG3.1OP
IC5Natural Gas Internal Combustion EngineNG3.1OP
IC6Natural Gas Internal Combustion EngineNG3.1OP
IC7Natural Gas Internal Combustion EngineNG3.1OP
IC8Natural Gas Internal Combustion EngineNG3.1OP
IC9Natural Gas Internal Combustion EngineNG3.1OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
56185
Sector
IPP Non-CHP
Water source
Municipality
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Chowchilla II power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Chowchilla II

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (2,063 MWh) and 5 the lowest (698 MWh). Their difference is 1,365 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
IC1Natural Gas Internal Combustion Engine3.13.13.12.1
IC10Natural Gas Internal Combustion Engine3.13.13.12.1
IC11Natural Gas Internal Combustion Engine3.13.13.12.1
IC12Natural Gas Internal Combustion Engine3.13.13.12.1
IC13Natural Gas Internal Combustion Engine3.13.13.12.1
IC14Natural Gas Internal Combustion Engine3.13.13.12.1
IC15Natural Gas Internal Combustion Engine3.13.13.12.1
IC16Natural Gas Internal Combustion Engine3.13.13.12.1
IC2Natural Gas Internal Combustion Engine3.13.13.12.1
IC3Natural Gas Internal Combustion Engine3.13.13.12.1
IC4Natural Gas Internal Combustion Engine3.13.13.12.1
IC5Natural Gas Internal Combustion Engine3.13.13.12.1
IC6Natural Gas Internal Combustion Engine3.13.13.12.1
IC7Natural Gas Internal Combustion Engine3.13.13.12.1
IC8Natural Gas Internal Combustion Engine3.13.13.12.1
IC9Natural Gas Internal Combustion Engine3.13.13.12.1

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check