MWPowerPlantFacts

Data last collected:

EIA plant 56516

Arvada · Jefferson · CO

Plains End II LLC

Operated by Plains End Operating Services LLC

Annual generation10,282 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextPublic Service Company of ColoradoBalancing authority or NERC region

Published location

Where is Plains End II LLC?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

39.858600, -105.225600

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Internal Combustion Engine117.6 MW represented

Grouped from this plant’s represented generator records. Use the CO plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

11,020.89
2845.08
3972.23
4743.81
5769.62
6896.54
71,224.64
81,122.33
9713.38
10582.64
11831.96
12558.89

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
11,020.89
2845.08
3972.23
4743.81
5769.62
6896.54
71,224.64
81,122.33
9713.38
10582.64
11831.96
12558.89

2024 monthly net generation

MonthNet generation
11,021 MWh
2845 MWh
3972 MWh
4744 MWh
5770 MWh
6897 MWh
71,225 MWh
81,122 MWh
9713 MWh
10583 MWh
11832 MWh
12559 MWh

Operating generators

IDTechnologyFuelMWStatus
2G01Natural Gas Internal Combustion EngineNG8.4OP
2G02Natural Gas Internal Combustion EngineNG8.4OP
2G03Natural Gas Internal Combustion EngineNG8.4OP
2G04Natural Gas Internal Combustion EngineNG8.4OP
2G05Natural Gas Internal Combustion EngineNG8.4OP
2G06Natural Gas Internal Combustion EngineNG8.4OP
2G07Natural Gas Internal Combustion EngineNG8.4OP
2G08Natural Gas Internal Combustion EngineNG8.4OP
2G09Natural Gas Internal Combustion EngineNG8.4OP
2G10Natural Gas Internal Combustion EngineNG8.4OP
2G11Natural Gas Internal Combustion EngineNG8.4OP
2G12Natural Gas Internal Combustion EngineNG8.4OP
2G13Natural Gas Internal Combustion EngineNG8.4OP
2G14Natural Gas Internal Combustion EngineNG8.4OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
56516
Sector
IPP Non-CHP
Water source
City of Arvada Oo Closed loop
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Plains End II LLC power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Plains End II LLC

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (1,225 MWh) and 12 the lowest (559 MWh). Their difference is 666 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
2G01Natural Gas Internal Combustion Engine8.48.048.044.2
2G02Natural Gas Internal Combustion Engine8.48.048.044.2
2G03Natural Gas Internal Combustion Engine8.48.048.044.2
2G04Natural Gas Internal Combustion Engine8.48.048.044.2
2G05Natural Gas Internal Combustion Engine8.48.048.044.2
2G06Natural Gas Internal Combustion Engine8.48.048.044.2
2G07Natural Gas Internal Combustion Engine8.47.48.34.2
2G08Natural Gas Internal Combustion Engine8.48.048.044.2
2G09Natural Gas Internal Combustion Engine8.48.048.044.2
2G10Natural Gas Internal Combustion Engine8.48.048.044.2
2G11Natural Gas Internal Combustion Engine8.48.048.044.2
2G12Natural Gas Internal Combustion Engine8.48.048.044.2
2G13Natural Gas Internal Combustion Engine8.48.048.044.2
2G14Natural Gas Internal Combustion Engine8.48.048.044.2

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check