MWPowerPlantFacts

Data last collected:

EIA plant 56998

Pueblo · Pueblo · CO

Pueblo Airport Generating Station

Operated by Black Hills Service Company LLC

Annual generation1,588,749 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextPublic Service Company of ColoradoBalancing authority or NERC region

Published location

Where is Pueblo Airport Generating Station?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

38.320833, -104.526390

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combustion Turbine240 MW represented
TechnologyNatural Gas Fired Combined Cycle200 MW represented

Grouped from this plant’s represented generator records. Use the CO plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1130,843
2123,673
3117,035
489,215
591,083
6133,175
7186,040
8187,477
9162,384
10111,377
11136,223
12120,224

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1130,843
2123,673
3117,035
489,215
591,083
6133,175
7186,040
8187,477
9162,384
10111,377
11136,223
12120,224

2024 monthly net generation

MonthNet generation
1130,843 MWh
2123,673 MWh
3117,035 MWh
489,215 MWh
591,083 MWh
6133,175 MWh
7186,040 MWh
8187,477 MWh
9162,384 MWh
10111,377 MWh
11136,223 MWh
12120,224 MWh

Operating generators

IDTechnologyFuelMWStatus
GT1Natural Gas Fired Combustion TurbineNG100OP
GT2Natural Gas Fired Combustion TurbineNG100OP
4Natural Gas Fired Combined CycleNG40OP
5Natural Gas Fired Combined CycleNG40OP
6Natural Gas Fired Combined CycleNG40OP
7Natural Gas Fired Combined CycleNG40OP
CT08Natural Gas Fired Combustion TurbineNG40OP
43Natural Gas Fired Combined CycleNG20OP
53Natural Gas Fired Combined CycleNG20OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
56998
Sector
IPP Non-CHP
Water source
City of Pueblo
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Pueblo Airport Generating Station power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Pueblo Airport Generating Station

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (187,477 MWh) and 4 the lowest (89,215 MWh). Their difference is 98,262 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 9 numeric rows displayed in this table, MW ranges from 20 (43, 53) to 100 (GT1, GT2). The difference is 80 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
4Natural Gas Fired Combined Cycle40.037.037.035.0
43Natural Gas Fired Combined Cycle20.020.020.010.0
5Natural Gas Fired Combined Cycle40.037.037.035.0
53Natural Gas Fired Combined Cycle20.020.020.010.0
6Natural Gas Fired Combined Cycle40.037.037.035.0
7Natural Gas Fired Combined Cycle40.037.037.035.0
CT08Natural Gas Fired Combustion Turbine40.040.040.018.0
GT1Natural Gas Fired Combustion Turbine100.090.090.035.0
GT2Natural Gas Fired Combustion Turbine100.090.090.035.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check