MWPowerPlantFacts

Data last collected:

EIA plant 57190

Niagara · Marinette · WI

Little Quinnesec Falls Hydro Project

Operated by Eagle Creek Renewable Energy, LLC

Annual generation56,603 MWhSum of represented EIA-923 rows
Fuel codesWATCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is Little Quinnesec Falls Hydro Project?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

45.773600, -87.989400

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyConventional Hydroelectric9 MW represented

Grouped from this plant’s represented generator records. Use the WI plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

15,086
25,173
35,667
45,574
56,291
65,701
75,158
83,146
92,449
102,857
114,865
124,636

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
15,086
25,173
35,667
45,574
56,291
65,701
75,158
83,146
92,449
102,857
114,865
124,636

2024 monthly net generation

MonthNet generation
15,086 MWh
25,173 MWh
35,667 MWh
45,574 MWh
56,291 MWh
65,701 MWh
75,158 MWh
83,146 MWh
92,449 MWh
102,857 MWh
114,865 MWh
124,636 MWh

Operating generators

IDTechnologyFuelMWStatus
UNIT6Conventional HydroelectricWAT2.4OP
UNIT1Conventional HydroelectricWAT1.9OP
UNIT3Conventional HydroelectricWAT1.9OP
UNIT4Conventional HydroelectricWAT1OP
UNIT5Conventional HydroelectricWAT1OP
UNIT2Conventional HydroelectricWAT0.8OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
57190
Sector
IPP Non-CHP
Water source
Menominee River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Little Quinnesec Falls Hydro Project power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Little Quinnesec Falls Hydro Project

Variation in the published months

Across 12 numeric monthly generation entries, 5 has the highest recorded value (6,291 MWh) and 9 the lowest (2,449 MWh). Their difference is 3,842 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 6 numeric rows displayed in this table, MW ranges from 0.8 (UNIT2) to 2.4 (UNIT6). The difference is 1.6 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
UNIT1Conventional Hydroelectric1.91.91.90.3
UNIT2Conventional Hydroelectric0.80.80.80.1
UNIT3Conventional Hydroelectric1.91.91.90.3
UNIT4Conventional Hydroelectric1.01.01.00.1
UNIT5Conventional Hydroelectric1.01.01.00.1
UNIT6Conventional Hydroelectric2.42.42.40.4

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check