MWPowerPlantFacts

Data last collected:

EIA plant 57707

Tonopah · Maricopa · AZ

Mesquite Solar 1

Operated by Consolidated Edison Development Inc.

Annual generation401,380 MWhSum of represented EIA-923 rows
Fuel codesSUNCodes retained from EIA records
Grid contextCalifornia Independent System OperatorBalancing authority or NERC region

Published location

Where is Mesquite Solar 1?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

33.341833, -112.904028

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologySolar Photovoltaic170 MW represented

Grouped from this plant’s represented generator records. Use the AZ plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

123,968
228,214
335,655
439,609
541,497
637,194
736,719
836,059
935,756
1034,509
1128,466
1223,734

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
123,968
228,214
335,655
439,609
541,497
637,194
736,719
836,059
935,756
1034,509
1128,466
1223,734

2024 monthly net generation

MonthNet generation
123,968 MWh
228,214 MWh
335,655 MWh
439,609 MWh
541,497 MWh
637,194 MWh
736,719 MWh
836,059 MWh
935,756 MWh
1034,509 MWh
1128,466 MWh
1223,734 MWh

Operating generators

IDTechnologyFuelMWStatus
1Solar PhotovoltaicSUN16OP
11Solar PhotovoltaicSUN16OP
12Solar PhotovoltaicSUN16OP
2Solar PhotovoltaicSUN16OP
4Solar PhotovoltaicSUN16OP
5Solar PhotovoltaicSUN16OP
7Solar PhotovoltaicSUN16OP
9Solar PhotovoltaicSUN16OP
10Solar PhotovoltaicSUN12OP
8Solar PhotovoltaicSUN12OP
3Solar PhotovoltaicSUN10OP
6Solar PhotovoltaicSUN8OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
57707
Sector
IPP Non-CHP
Water source
Unavailable
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Mesquite Solar 1 power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Mesquite Solar 1

Variation in the published months

Across 12 numeric monthly generation entries, 5 has the highest recorded value (41,497 MWh) and 12 the lowest (23,734 MWh). Their difference is 17,763 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 12 numeric rows displayed in this table, MW ranges from 8 (6) to 16 (1, 11, 12). The difference is 8 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Solar Photovoltaic16.016.016.0Not supplied
10Solar Photovoltaic12.012.012.0Not supplied
11Solar Photovoltaic16.016.016.0Not supplied
12Solar Photovoltaic16.016.016.0Not supplied
2Solar Photovoltaic16.016.016.0Not supplied
3Solar Photovoltaic10.010.010.0Not supplied
4Solar Photovoltaic16.016.016.0Not supplied
5Solar Photovoltaic16.016.016.0Not supplied
6Solar Photovoltaic8.08.08.0Not supplied
7Solar Photovoltaic16.016.016.0Not supplied
8Solar Photovoltaic12.012.012.0Not supplied
9Solar Photovoltaic16.016.016.0Not supplied

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check