MWPowerPlantFacts

Data last collected:

EIA plant 57865

Abernathy · Hale · TX

Antelope Station

Operated by Golden Spread Electric Cooperative, Inc

Annual generation267,063 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextSouthwest Power PoolBalancing authority or NERC region

Published location

Where is Antelope Station?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

33.865000, -101.843333

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Internal Combustion Engine167.4 MW represented

Grouped from this plant’s represented generator records. Use the TX plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

123,074.97
215,931.39
318,079.16
416,985.8
522,694.91
625,603.9
727,675.79
831,271.78
925,947.09
1022,475.89
1118,006.16
1219,316.16

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
123,074.97
215,931.39
318,079.16
416,985.8
522,694.91
625,603.9
727,675.79
831,271.78
925,947.09
1022,475.89
1118,006.16
1219,316.16

2024 monthly net generation

MonthNet generation
123,075 MWh
215,931 MWh
318,079 MWh
416,986 MWh
522,695 MWh
625,604 MWh
727,676 MWh
831,272 MWh
925,947 MWh
1022,476 MWh
1118,006 MWh
1219,316 MWh

Operating generators

IDTechnologyFuelMWStatus
E01Natural Gas Internal Combustion EngineNG9.3OP
E02Natural Gas Internal Combustion EngineNG9.3OP
E03Natural Gas Internal Combustion EngineNG9.3OP
E04Natural Gas Internal Combustion EngineNG9.3OP
E05Natural Gas Internal Combustion EngineNG9.3OP
E06Natural Gas Internal Combustion EngineNG9.3OP
E07Natural Gas Internal Combustion EngineNG9.3OP
E08Natural Gas Internal Combustion EngineNG9.3OP
E09Natural Gas Internal Combustion EngineNG9.3OP
E10Natural Gas Internal Combustion EngineNG9.3OP
E11Natural Gas Internal Combustion EngineNG9.3OP
E12Natural Gas Internal Combustion EngineNG9.3OP
E13Natural Gas Internal Combustion EngineNG9.3OP
E14Natural Gas Internal Combustion EngineNG9.3OP
E15Natural Gas Internal Combustion EngineNG9.3OP
E16Natural Gas Internal Combustion EngineNG9.3OP
E17Natural Gas Internal Combustion EngineNG9.3OP
E18Natural Gas Internal Combustion EngineNG9.3OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
57865
Sector
Electric Utility
Water source
Unavailable
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Antelope Station power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Antelope Station

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (31,272 MWh) and 2 the lowest (15,931 MWh). Their difference is 15,341 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
E01Natural Gas Internal Combustion Engine9.39.09.33.7
E02Natural Gas Internal Combustion Engine9.39.19.33.7
E03Natural Gas Internal Combustion Engine9.39.09.33.7
E04Natural Gas Internal Combustion Engine9.39.09.33.7
E05Natural Gas Internal Combustion Engine9.39.09.33.7
E06Natural Gas Internal Combustion Engine9.39.19.33.7
E07Natural Gas Internal Combustion Engine9.38.79.33.7
E08Natural Gas Internal Combustion Engine9.39.19.33.7
E09Natural Gas Internal Combustion Engine9.39.29.33.7
E10Natural Gas Internal Combustion Engine9.39.19.33.7
E11Natural Gas Internal Combustion Engine9.39.19.33.7
E12Natural Gas Internal Combustion Engine9.38.99.33.7
E13Natural Gas Internal Combustion Engine9.39.19.33.7
E14Natural Gas Internal Combustion Engine9.39.09.33.7
E15Natural Gas Internal Combustion Engine9.39.19.33.7
E16Natural Gas Internal Combustion Engine9.38.49.33.7
E17Natural Gas Internal Combustion Engine9.39.19.33.7
E18Natural Gas Internal Combustion Engine9.39.09.33.7

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check