MWPowerPlantFacts

Data last collected:

EIA plant 58159

Storrs · Tolland · CT

UCONN Cogen Facility

Operated by University of Connecticut

Annual generation122,717 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextISO New England Inc.Balancing authority or NERC region

Published location

Where is UCONN Cogen Facility?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

41.809167, -72.254167

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle25.7 MW represented

Grouped from this plant’s represented generator records. Use the CT plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

110,651
210,577
310,683
49,789
53,230
610,930
712,000
811,573
911,074
1011,418
1110,008
1210,784

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
110,651
210,577
310,683
49,789
53,230
610,930
712,000
811,573
911,074
1011,418
1110,008
1210,784

2024 monthly net generation

MonthNet generation
110,651 MWh
210,577 MWh
310,683 MWh
49,789 MWh
53,230 MWh
610,930 MWh
712,000 MWh
811,573 MWh
911,074 MWh
1011,418 MWh
1110,008 MWh
1210,784 MWh

Operating generators

IDTechnologyFuelMWStatus
CGT1Natural Gas Fired Combined CycleNG6.9OP
CGT2Natural Gas Fired Combined CycleNG6.9OP
CGT3Natural Gas Fired Combined CycleNG6.9OP
STG1Natural Gas Fired Combined CycleNG5OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
58159
Sector
Commercial CHP
Water source
UCONN Well Fields
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right UCONN Cogen Facility power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at UCONN Cogen Facility

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (12,000 MWh) and 5 the lowest (3,230 MWh). Their difference is 8,770 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 4 numeric rows displayed in this table, MW ranges from 5 (STG1) to 6.9 (CGT1, CGT2, CGT3). The difference is 1.9 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CGT1Natural Gas Fired Combined Cycle6.96.46.43.2
CGT2Natural Gas Fired Combined Cycle6.96.46.43.2
CGT3Natural Gas Fired Combined Cycle6.96.46.43.2
STG1Natural Gas Fired Combined Cycle5.04.94.90.2

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.