MWPowerPlantFacts

Data last collected:

EIA plant 58207

Silver Spring · Montgomery · MD

Central Utility Plant at White Oak

Operated by GSA Metropolitan Service Center

Annual generation74,045 MWhSum of represented EIA-923 rows
Fuel codesNG, DFOCodes retained from EIA records
Grid contextPJM Interconnection, LLCBalancing authority or NERC region

Published location

Where is Central Utility Plant at White Oak?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

39.039444, -76.982500

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle24.5 MW represented
TechnologyNatural Gas Fired Combustion Turbine17.2 MW represented
TechnologyPetroleum Liquids6.9 MW represented
TechnologyNatural Gas Internal Combustion Engine5.7 MW represented

Grouped from this plant’s represented generator records. Use the MD plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

18,028.63
27,429.34
47,918.98
58,603.83
79,652.92
89,227.04
107,899.02
117,516.44
127,768.88

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 9 of 9 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
18,028.63
27,429.34
47,918.98
58,603.83
79,652.92
89,227.04
107,899.02
117,516.44
127,768.88

2024 monthly net generation

MonthNet generation
18,029 MWh
27,429 MWh
47,919 MWh
58,604 MWh
79,653 MWh
89,227 MWh
107,899 MWh
117,516 MWh
127,769 MWh

Operating generators

IDTechnologyFuelMWStatus
G7Natural Gas Fired Combined CycleNG7.5OP
G8Natural Gas Fired Combined CycleNG7.5OP
G1Natural Gas Internal Combustion EngineNG5.7OP
G12Natural Gas Fired Combined CycleNG5OP
G9Natural Gas Fired Combined CycleNG4.5OP
G3Natural Gas Fired Combustion TurbineNG4.3OP
G4Natural Gas Fired Combustion TurbineNG4.3OP
G5Natural Gas Fired Combustion TurbineNG4.3OP
G6Natural Gas Fired Combustion TurbineNG4.3OP
G10Petroleum LiquidsDFO2.3OP
G11Petroleum LiquidsDFO2.3OP
G2Petroleum LiquidsDFO2.3SB

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
58207
Sector
Commercial CHP
Water source
Municipality - WSSC
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Central Utility Plant at White Oak power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Central Utility Plant at White Oak

Variation in the published months

Across 9 numeric monthly generation entries, 7 has the highest recorded value (9,653 MWh) and 2 the lowest (7,429 MWh). Their difference is 2,224 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 12 numeric rows displayed in this table, MW ranges from 2.3 (G10, G11, G2) to 7.5 (G7, G8). The difference is 5.2 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
G1Natural Gas Internal Combustion Engine5.75.65.61.0
G10Petroleum Liquids2.32.32.30.5
G11Petroleum Liquids2.32.32.30.5
G12Natural Gas Fired Combined Cycle5.05.05.00.5
G2Petroleum Liquids2.32.32.30.5
G3Natural Gas Fired Combustion Turbine4.34.34.60.5
G4Natural Gas Fired Combustion Turbine4.34.34.60.5
G5Natural Gas Fired Combustion Turbine4.34.34.60.5
G6Natural Gas Fired Combustion Turbine4.34.34.60.5
G7Natural Gas Fired Combined Cycle7.57.57.50.5
G8Natural Gas Fired Combined Cycle7.57.57.50.5
G9Natural Gas Fired Combined Cycle4.54.54.50.5

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check