MWPowerPlantFacts

Data last collected:

EIA plant 58382

Boardman · Morrow · OR

Threemile Digester

Operated by TMF-RIG, LLC

Annual generation36,434 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextPacifiCorp - WestBalancing authority or NERC region

Published location

Where is Threemile Digester?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

45.710000, -119.901111

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Internal Combustion Engine4.8 MW represented

Grouped from this plant’s represented generator records. Use the OR plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

13,558.13
23,188.61
33,105.24
42,651
51,150.52
62,434.14
73,423.71
83,536.77
93,478.37
103,102.62
113,302.16
123,502.73

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
13,558.13
23,188.61
33,105.24
42,651
51,150.52
62,434.14
73,423.71
83,536.77
93,478.37
103,102.62
113,302.16
123,502.73

2024 monthly net generation

MonthNet generation
13,558 MWh
23,189 MWh
33,105 MWh
42,651 MWh
51,151 MWh
62,434 MWh
73,424 MWh
83,537 MWh
93,478 MWh
103,103 MWh
113,302 MWh
123,503 MWh

Operating generators

IDTechnologyFuelMWStatus
GEN1Natural Gas Internal Combustion EngineNG1.6OP
GEN2Natural Gas Internal Combustion EngineNG1.6OP
GEN3Natural Gas Internal Combustion EngineNG1.6OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
58382
Sector
IPP CHP
Water source
Wells
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Threemile Digester power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Threemile Digester

Variation in the published months

Across 12 numeric monthly generation entries, 1 has the highest recorded value (3,558 MWh) and 5 the lowest (1,151 MWh). Their difference is 2,407 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
GEN1Natural Gas Internal Combustion Engine1.61.61.60.8
GEN2Natural Gas Internal Combustion Engine1.61.61.60.8
GEN3Natural Gas Internal Combustion Engine1.61.61.60.8

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check