MWPowerPlantFacts

Data last collected:

EIA plant 58870

Pasadena · Harris · TX

Rentech Nitrogen Pasadena Cogeneration

Operated by PCI Nitrogen LLC

Annual generation52,542 MWhSum of represented EIA-923 rows
Fuel codesWHCodes retained from EIA records
Grid contextElectric Reliability Council of Texas, Inc.Balancing authority or NERC region

Published location

Where is Rentech Nitrogen Pasadena Cogeneration?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

29.739444, -95.194722

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyAll Other15.4 MW represented

Grouped from this plant’s represented generator records. Use the TX plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

11,849
25,644
35,055
46,427
56,520
61,434
73,385
86,849
96,548
105,737
1152
123,042

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
11,849
25,644
35,055
46,427
56,520
61,434
73,385
86,849
96,548
105,737
1152
123,042

2024 monthly net generation

MonthNet generation
11,849 MWh
25,644 MWh
35,055 MWh
46,427 MWh
56,520 MWh
61,434 MWh
73,385 MWh
86,849 MWh
96,548 MWh
105,737 MWh
1152 MWh
123,042 MWh

Operating generators

IDTechnologyFuelMWStatus
MG202All OtherWH15.4OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
58870
Sector
IPP CHP
Water source
Municipality
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Rentech Nitrogen Pasadena Cogeneration power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Rentech Nitrogen Pasadena Cogeneration

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (6,849 MWh) and 11 the lowest (52 MWh). Their difference is 6,797 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
MG202All Other15.414.014.24.2

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.