MWPowerPlantFacts

Data last collected:

EIA plant 59425

Argos · Marshall · IN

Zimmerman Energy

Operated by Landfill Energy Systems

Annual generation38,402 MWhSum of represented EIA-923 rows
Fuel codesLFGCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is Zimmerman Energy?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

41.237778, -86.246111

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyLandfill Gas7.6 MW represented

Grouped from this plant’s represented generator records. Use the IN plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

14,592
23,935
33,988
43,459
52,258
62,650
72,846
83,158
92,531
103,223
112,966
122,796

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
14,592
23,935
33,988
43,459
52,258
62,650
72,846
83,158
92,531
103,223
112,966
122,796

2024 monthly net generation

MonthNet generation
14,592 MWh
23,935 MWh
33,988 MWh
43,459 MWh
52,258 MWh
62,650 MWh
72,846 MWh
83,158 MWh
92,531 MWh
103,223 MWh
112,966 MWh
122,796 MWh

Operating generators

IDTechnologyFuelMWStatus
ZE-#1Landfill GasLFG2OP
ZE-#2Landfill GasLFG2OP
ZE-#3Landfill GasLFG2OP
ZE#4Landfill GasLFG1.6OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
59425
Sector
IPP Non-CHP
Water source
Unavailable
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Zimmerman Energy power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Zimmerman Energy

Variation in the published months

Across 12 numeric monthly generation entries, 1 has the highest recorded value (4,592 MWh) and 5 the lowest (2,258 MWh). Their difference is 2,334 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 4 numeric rows displayed in this table, MW ranges from 1.6 (ZE#4) to 2 (ZE-#1, ZE-#2, ZE-#3). The difference is 0.4 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
ZE#4Landfill Gas1.61.41.40.8
ZE-#1Landfill Gas2.01.91.90.9
ZE-#2Landfill Gas2.01.91.90.9
ZE-#3Landfill Gas2.01.91.90.9

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.