MWPowerPlantFacts

Data last collected:

EIA plant 59812

Granbury · Hood · TX

Wolf Hollow II

Operated by Constellation Power, Inc

Annual generation6,461,028 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextElectric Reliability Council of Texas, Inc.Balancing authority or NERC region

Published location

Where is Wolf Hollow II?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

32.337679, -97.734612

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle1,231.2 MW represented

Grouped from this plant’s represented generator records. Use the TX plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1684,318
2528,544
3634,982
4347,134
5485,419
6703,188
7718,006
8748,369
9682,483
10627,446
11143,147
12157,992

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1684,318
2528,544
3634,982
4347,134
5485,419
6703,188
7718,006
8748,369
9682,483
10627,446
11143,147
12157,992

2024 monthly net generation

MonthNet generation
1684,318 MWh
2528,544 MWh
3634,982 MWh
4347,134 MWh
5485,419 MWh
6703,188 MWh
7718,006 MWh
8748,369 MWh
9682,483 MWh
10627,446 MWh
11143,147 MWh
12157,992 MWh

Operating generators

IDTechnologyFuelMWStatus
STG6Natural Gas Fired Combined CycleNG511.2OP
CGT4Natural Gas Fired Combined CycleNG360OP
CGT5Natural Gas Fired Combined CycleNG360OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
59812
Sector
IPP Non-CHP
Water source
NA
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Wolf Hollow II power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Wolf Hollow II

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (748,369 MWh) and 11 the lowest (143,147 MWh). Their difference is 605,222 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 360 (CGT4, CGT5) to 511.2 (STG6). The difference is 151.2 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CGT4Natural Gas Fired Combined Cycle360.0327.8353.3113.0
CGT5Natural Gas Fired Combined Cycle360.0329.3354.6113.0
STG6Natural Gas Fired Combined Cycle511.2446.3473.160.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research