MWPowerPlantFacts

Data last collected:

EIA plant 60647

Shakopee · Scott · MN

Shakopee Energy Park

Operated by Minnesota Municipal Power Agny

Annual generation23,959 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is Shakopee Energy Park?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

44.783611, -93.481111

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Internal Combustion Engine46.5 MW represented

Grouped from this plant’s represented generator records. Use the MN plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

12,156.92
21,943.5
31,984.94
41,277.08
51,504.43
61,795.36
73,008.82
82,812.78
91,813.68
101,288.91
112,084.11
122,288.47

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
12,156.92
21,943.5
31,984.94
41,277.08
51,504.43
61,795.36
73,008.82
82,812.78
91,813.68
101,288.91
112,084.11
122,288.47

2024 monthly net generation

MonthNet generation
12,157 MWh
21,943 MWh
31,985 MWh
41,277 MWh
51,504 MWh
61,795 MWh
73,009 MWh
82,813 MWh
91,814 MWh
101,289 MWh
112,084 MWh
122,288 MWh

Operating generators

IDTechnologyFuelMWStatus
SQA01Natural Gas Internal Combustion EngineNG9.3OP
SQA02Natural Gas Internal Combustion EngineNG9.3OP
SQA03Natural Gas Internal Combustion EngineNG9.3OP
SQA04Natural Gas Internal Combustion EngineNG9.3OP
SQA05Natural Gas Internal Combustion EngineNG9.3OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
60647
Sector
Electric Utility
Water source
Municipality
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Shakopee Energy Park power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Shakopee Energy Park

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (3,009 MWh) and 4 the lowest (1,277 MWh). Their difference is 1,732 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
SQA01Natural Gas Internal Combustion Engine9.39.39.33.0
SQA02Natural Gas Internal Combustion Engine9.39.39.33.0
SQA03Natural Gas Internal Combustion Engine9.39.39.33.0
SQA04Natural Gas Internal Combustion Engine9.39.39.33.0
SQA05Natural Gas Internal Combustion Engine9.39.39.33.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.