MWPowerPlantFacts

Data last collected:

EIA plant 6103

Berwick · Luzerne · PA

TalenEnergy Susquehanna

Operated by TalenEnergy Susquehanna LLC

Annual generation19,744,444 MWhSum of represented EIA-923 rows
Fuel codesNUCCodes retained from EIA records
Grid contextPJM Interconnection, LLCBalancing authority or NERC region

Published location

Where is TalenEnergy Susquehanna?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

41.091900, -76.146200

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNuclear2,532 MW represented

Grouped from this plant’s represented generator records. Use the PA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

11,751,969
21,632,208
31,461,496
4878,917
51,804,995
61,727,658
71,733,799
81,788,118
91,576,135
101,817,979
111,748,160
121,823,010

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
11,751,969
21,632,208
31,461,496
4878,917
51,804,995
61,727,658
71,733,799
81,788,118
91,576,135
101,817,979
111,748,160
121,823,010

2024 monthly net generation

MonthNet generation
11,751,969 MWh
21,632,208 MWh
31,461,496 MWh
4878,917 MWh
51,804,995 MWh
61,727,658 MWh
71,733,799 MWh
81,788,118 MWh
91,576,135 MWh
101,817,979 MWh
111,748,160 MWh
121,823,010 MWh

Operating generators

IDTechnologyFuelMWStatus
1NuclearNUC1,266OP
2NuclearNUC1,266OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
6103
Sector
IPP Non-CHP
Water source
Susquehanna River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right TalenEnergy Susquehanna power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at TalenEnergy Susquehanna

Variation in the published months

Across 12 numeric monthly generation entries, 12 has the highest recorded value (1,823,010 MWh) and 4 the lowest (878,917 MWh). Their difference is 944,093 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Nuclear1266.01247.01247.0170.0
2Nuclear1266.01247.01247.0170.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.