MWPowerPlantFacts

Data last collected:

EIA plant 62270

Valhalla · Westchester · NY

Westchester County Medical Center

Operated by Westchester County Medical Center

Annual generation285 MWhSum of represented EIA-923 rows
Fuel codesDFOCodes retained from EIA records
Grid contextNew York Independent System OperatorBalancing authority or NERC region

Published location

Where is Westchester County Medical Center?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

41.089210, -73.804430

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyPetroleum Liquids8.9 MW represented

Grouped from this plant’s represented generator records. Use the NY plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1115.71
25.46
334.49
48.32
54.19
63.39
76.77
84.47
94.19
107.58
1110.63
1279.8

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1115.71
25.46
334.49
48.32
54.19
63.39
76.77
84.47
94.19
107.58
1110.63
1279.8

2024 monthly net generation

MonthNet generation
1116 MWh
25 MWh
334 MWh
48 MWh
54 MWh
63 MWh
77 MWh
84 MWh
94 MWh
108 MWh
1111 MWh
1280 MWh

Operating generators

IDTechnologyFuelMWStatus
CAT2CPetroleum LiquidsDFO1.5SB
CATH1Petroleum LiquidsDFO1.3SB
CATH2Petroleum LiquidsDFO1.3SB
CAT04Petroleum LiquidsDFO0.7SB
CATN1Petroleum LiquidsDFO0.7SB
CATN2Petroleum LiquidsDFO0.7SB
CATN3Petroleum LiquidsDFO0.7SB
CATR3Petroleum LiquidsDFO0.6SB
DT080Petroleum LiquidsDFO0.5SB
DT500Petroleum LiquidsDFO0.5SB
CUM37Petroleum LiquidsDFO0.4SB

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
62270
Sector
Commercial Non-CHP
Water source
Unavailable
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Westchester County Medical Center power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Westchester County Medical Center

Variation in the published months

Across 12 numeric monthly generation entries, 1 has the highest recorded value (116 MWh) and 6 the lowest (3 MWh). Their difference is 113 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 11 numeric rows displayed in this table, MW ranges from 0.4 (CUM37) to 1.5 (CAT2C). The difference is 1.1 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CAT04Petroleum Liquids0.70.70.70.1
CAT2CPetroleum Liquids1.51.51.50.3
CATH1Petroleum Liquids1.31.31.30.1
CATH2Petroleum Liquids1.31.31.30.1
CATN1Petroleum Liquids0.70.70.70.1
CATN2Petroleum Liquids0.70.70.70.1
CATN3Petroleum Liquids0.70.70.70.1
CATR3Petroleum Liquids0.60.60.60.1
CUM37Petroleum Liquids0.40.40.40.1
DT080Petroleum Liquids0.50.50.50.1
DT500Petroleum Liquids0.50.50.50.1

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check