MWPowerPlantFacts

Data last collected:

EIA plant 65840

Pattersonville · Schenectady · NY

NY8 - Teichos Pattersonville

Operated by MN8 Energy LLC

Annual generation33,654 MWhSum of represented EIA-923 rows
Fuel codesSUNCodes retained from EIA records
Grid contextNew York Independent System OperatorBalancing authority or NERC region

Published location

Where is NY8 - Teichos Pattersonville?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

42.880800, -74.095100

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologySolar Photovoltaic20 MW represented

Grouped from this plant’s represented generator records. Use the NY plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

10
2324
32,312
43,281
54,557
64,289
75,243
83,759
94,149
103,113
111,811
12816

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
10
2324
32,312
43,281
54,557
64,289
75,243
83,759
94,149
103,113
111,811
12816

2024 monthly net generation

MonthNet generation
10 MWh
2324 MWh
32,312 MWh
43,281 MWh
54,557 MWh
64,289 MWh
75,243 MWh
83,759 MWh
94,149 MWh
103,113 MWh
111,811 MWh
12816 MWh

Operating generators

IDTechnologyFuelMWStatus
GEN1Solar PhotovoltaicSUN20OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
65840
Sector
IPP Non-CHP
Water source
Unavailable
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right NY8 - Teichos Pattersonville power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at NY8 - Teichos Pattersonville

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (5,243 MWh) and 1 the lowest (0 MWh). Their difference is 5,243 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
GEN1Solar Photovoltaic20.020.020.0Not supplied

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check