MWPowerPlantFacts

Data last collected:

EIA plant 688

Tallahassee · Leon · FL

Arvah B Hopkins

Operated by City of Tallahassee - (FL)

Annual generation1,751,819 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextCity of TallahasseeBalancing authority or NERC region

Published location

Where is Arvah B Hopkins?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

30.452200, -84.400000

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle458.1 MW represented
TechnologyNatural Gas Fired Combustion Turbine121 MW represented
TechnologyNatural Gas Internal Combustion Engine94 MW represented

Grouped from this plant’s represented generator records. Use the FL plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1142,920
2124,895
372,757
4137,548
5144,070
6150,481
7165,705
8168,482
9148,674
10130,626
11195,986
12169,675

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1142,920
2124,895
372,757
4137,548
5144,070
6150,481
7165,705
8168,482
9148,674
10130,626
11195,986
12169,675

2024 monthly net generation

MonthNet generation
1142,920 MWh
2124,895 MWh
372,757 MWh
4137,548 MWh
5144,070 MWh
6150,481 MWh
7165,705 MWh
8168,482 MWh
9148,674 MWh
10130,626 MWh
11195,986 MWh
12169,675 MWh

Operating generators

IDTechnologyFuelMWStatus
2Natural Gas Fired Combined CycleNG259.2OP
CT 2ANatural Gas Fired Combined CycleNG198.9OP
GT3Natural Gas Fired Combustion TurbineNG60.5OP
GT4Natural Gas Fired Combustion TurbineNG60.5OP
IC1Natural Gas Internal Combustion EngineNG18.8OP
IC2Natural Gas Internal Combustion EngineNG18.8OP
IC3Natural Gas Internal Combustion EngineNG18.8OP
IC4Natural Gas Internal Combustion EngineNG18.8OP
IC5Natural Gas Internal Combustion EngineNG18.8OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
688
Sector
Electric Utility
Water source
Wells
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Arvah B Hopkins power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Arvah B Hopkins

Variation in the published months

Across 12 numeric monthly generation entries, 11 has the highest recorded value (195,986 MWh) and 3 the lowest (72,757 MWh). Their difference is 123,229 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 9 numeric rows displayed in this table, MW ranges from 18.8 (IC1, IC2, IC3) to 259.2 (2). The difference is 240.4 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
2Natural Gas Fired Combined Cycle259.2141.0145.0110.0
CT 2ANatural Gas Fired Combined Cycle198.9159.0185.056.0
GT3Natural Gas Fired Combustion Turbine60.546.048.012.0
GT4Natural Gas Fired Combustion Turbine60.546.048.012.0
IC1Natural Gas Internal Combustion Engine18.818.518.57.5
IC2Natural Gas Internal Combustion Engine18.818.518.57.5
IC3Natural Gas Internal Combustion Engine18.818.518.57.5
IC4Natural Gas Internal Combustion Engine18.818.518.57.5
IC5Natural Gas Internal Combustion Engine18.818.518.57.5

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check