MWPowerPlantFacts

Data last collected:

EIA plant 8006

Newsburgh · Orange · NY

Roseton Generating Facility

Operated by CCI Roseton LLC

Annual generation236,658 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextNew York Independent System OperatorBalancing authority or NERC region

Published location

Where is Roseton Generating Facility?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

41.573783, -73.966269

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Steam Turbine1,242 MW represented

Grouped from this plant’s represented generator records. Use the NY plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

121,884
20
30
46,739
50
650,780
798,401
850,795
98,048
100
1111
120

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
121,884
20
30
46,739
50
650,780
798,401
850,795
98,048
100
1111
120

2024 monthly net generation

MonthNet generation
121,884 MWh
20 MWh
30 MWh
46,739 MWh
50 MWh
650,780 MWh
798,401 MWh
850,795 MWh
98,048 MWh
100 MWh
1111 MWh
120 MWh

Operating generators

IDTechnologyFuelMWStatus
1Natural Gas Steam TurbineNG621OP
2Natural Gas Steam TurbineNG621OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
8006
Sector
IPP Non-CHP
Water source
Hudson River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Roseton Generating Facility power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Roseton Generating Facility

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (98,401 MWh) and 2, 3, 5, 10, 12 the lowest (0 MWh). Their difference is 98,401 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Natural Gas Steam Turbine621.0614.8613.2140.0
2Natural Gas Steam Turbine621.0607.7607.7140.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check