MWPowerPlantFacts

Data last collected:

EIA plant 1912

St. Paul · Ramsey · MN

High Bridge

Operated by Northern States Power Co - Minnesota

Annual generation3,042,688 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is High Bridge?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

44.931400, -93.111700

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle644 MW represented

Grouped from this plant’s represented generator records. Use the MN plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1331,495
2289,083
3345,492
4211,280
5247,931
6238,260
7358,661
8370,970
9129,776
10131.56
11180,344
12339,264

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1331,495
2289,083
3345,492
4211,280
5247,931
6238,260
7358,661
8370,970
9129,776
10131.56
11180,344
12339,264

2024 monthly net generation

MonthNet generation
1331,495 MWh
2289,083 MWh
3345,492 MWh
4211,280 MWh
5247,931 MWh
6238,260 MWh
7358,661 MWh
8370,970 MWh
9129,776 MWh
10132 MWh
11180,344 MWh
12339,264 MWh

Operating generators

IDTechnologyFuelMWStatus
9Natural Gas Fired Combined CycleNG250OP
7Natural Gas Fired Combined CycleNG197OP
8Natural Gas Fired Combined CycleNG197OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
1912
Sector
Electric Utility
Water source
Mississippi River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right High Bridge power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at High Bridge

Variation in the published months

Across 12 numeric monthly generation entries, 8 has the highest recorded value (370,970 MWh) and 10 the lowest (132 MWh). Their difference is 370,838 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 197 (7, 8) to 250 (9). The difference is 53 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
7Natural Gas Fired Combined Cycle197.0152.0172.088.0
8Natural Gas Fired Combined Cycle197.0152.0172.088.0
9Natural Gas Fired Combined Cycle250.0226.0236.0162.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.