MWPowerPlantFacts

Data last collected:

EIA plant 2511

Island Park · Nassau · NY

E F Barrett

Operated by National Grid Generation LLC

Annual generation1,183,540 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextNew York Independent System OperatorBalancing authority or NERC region

Published location

Where is E F Barrett?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

40.616689, -73.647881

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Steam Turbine376 MW represented
TechnologyNatural Gas Fired Combustion Turbine293.2 MW represented

Grouped from this plant’s represented generator records. Use the NY plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

191,393
286,089
373,949
470,295
544,426
693,218
7182,127
8164,857
9127,008
1046,220
1176,608
12127,350

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
191,393
286,089
373,949
470,295
544,426
693,218
7182,127
8164,857
9127,008
1046,220
1176,608
12127,350

2024 monthly net generation

MonthNet generation
191,393 MWh
286,089 MWh
373,949 MWh
470,295 MWh
544,426 MWh
693,218 MWh
7182,127 MWh
8164,857 MWh
9127,008 MWh
1046,220 MWh
1176,608 MWh
12127,350 MWh

Operating generators

IDTechnologyFuelMWStatus
ST1Natural Gas Steam TurbineNG188OP
ST2Natural Gas Steam TurbineNG188OP
10Natural Gas Fired Combustion TurbineNG41.8OP
11Natural Gas Fired Combustion TurbineNG41.8OP
12Natural Gas Fired Combustion TurbineNG41.8OP
9Natural Gas Fired Combustion TurbineNG41.8OP
3Natural Gas Fired Combustion TurbineNG18OP
4Natural Gas Fired Combustion TurbineNG18OP
5Natural Gas Fired Combustion TurbineNG18OP
6Natural Gas Fired Combustion TurbineNG18OP
8Natural Gas Fired Combustion TurbineNG18OP
GT1Natural Gas Fired Combustion TurbineNG18OP
GT2Natural Gas Fired Combustion TurbineNG18OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
2511
Sector
Electric Utility
Water source
Barnum Island Channel
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right E F Barrett power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at E F Barrett

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (182,127 MWh) and 5 the lowest (44,426 MWh). Their difference is 137,701 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 13 numeric rows displayed in this table, MW ranges from 18 (3, 4, 5) to 188 (ST1, ST2). The difference is 170 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
10Natural Gas Fired Combustion Turbine41.840.650.030.0
11Natural Gas Fired Combustion Turbine41.840.150.530.0
12Natural Gas Fired Combustion Turbine41.840.948.730.0
3Natural Gas Fired Combustion Turbine18.017.720.210.5
4Natural Gas Fired Combustion Turbine18.016.820.511.4
5Natural Gas Fired Combustion Turbine18.017.620.111.0
6Natural Gas Fired Combustion Turbine18.016.419.911.2
8Natural Gas Fired Combustion Turbine18.015.115.211.4
9Natural Gas Fired Combustion Turbine41.841.249.229.8
GT1Natural Gas Fired Combustion Turbine18.017.420.510.7
GT2Natural Gas Fired Combustion Turbine18.017.620.49.0
ST1Natural Gas Steam Turbine188.0194.2199.515.0
ST2Natural Gas Steam Turbine188.0178.0190.515.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check