MWPowerPlantFacts

Data last collected:

EIA plant 2494

Brooklyn · Kings · NY

Gowanus Gas Turbines Generating

Operated by U S Power Generating Company LLC

Annual generation10,920 MWhSum of represented EIA-923 rows
Fuel codesDFO, NGCodes retained from EIA records
Grid contextNew York Independent System OperatorBalancing authority or NERC region

Published location

Where is Gowanus Gas Turbines Generating?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

40.663500, -74.005100

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyPetroleum Liquids320 MW represented
TechnologyNatural Gas Fired Combustion Turbine320 MW represented

Grouped from this plant’s represented generator records. Use the NY plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1394.75
2226.16
329.84
4206.2
582.44
65,766.74
72,085.35
81,458.22
9184.6
10199.83
11284.61
121.25

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1394.75
2226.16
329.84
4206.2
582.44
65,766.74
72,085.35
81,458.22
9184.6
10199.83
11284.61
121.25

2024 monthly net generation

MonthNet generation
1395 MWh
2226 MWh
330 MWh
4206 MWh
582 MWh
65,767 MWh
72,085 MWh
81,458 MWh
9185 MWh
10200 MWh
11285 MWh
121 MWh

Operating generators

IDTechnologyFuelMWStatus
GT11Petroleum LiquidsDFO20OP
GT12Petroleum LiquidsDFO20OP
GT13Petroleum LiquidsDFO20OP
GT14Petroleum LiquidsDFO20OP
GT15Petroleum LiquidsDFO20OP
GT16Petroleum LiquidsDFO20OP
GT17Petroleum LiquidsDFO20OP
GT18Petroleum LiquidsDFO20OS
GT21Natural Gas Fired Combustion TurbineNG20OP
GT22Natural Gas Fired Combustion TurbineNG20OP
GT23Natural Gas Fired Combustion TurbineNG20OP
GT24Natural Gas Fired Combustion TurbineNG20OP
GT25Natural Gas Fired Combustion TurbineNG20OP
GT26Natural Gas Fired Combustion TurbineNG20OP
GT27Natural Gas Fired Combustion TurbineNG20OP
GT28Natural Gas Fired Combustion TurbineNG20OP
GT31Natural Gas Fired Combustion TurbineNG20OP
GT32Natural Gas Fired Combustion TurbineNG20OP
GT33Natural Gas Fired Combustion TurbineNG20OP
GT34Natural Gas Fired Combustion TurbineNG20OP
GT35Natural Gas Fired Combustion TurbineNG20OP
GT36Natural Gas Fired Combustion TurbineNG20OP
GT37Natural Gas Fired Combustion TurbineNG20OP
GT38Natural Gas Fired Combustion TurbineNG20OP
GT41Petroleum LiquidsDFO20OP
GT42Petroleum LiquidsDFO20OP
GT43Petroleum LiquidsDFO20OP
GT44Petroleum LiquidsDFO20OP
GT45Petroleum LiquidsDFO20OP
GT46Petroleum LiquidsDFO20OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
2494
Sector
IPP Non-CHP
Water source
Municipality
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Gowanus Gas Turbines Generating power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Gowanus Gas Turbines Generating

Variation in the published months

Across 12 numeric monthly generation entries, 6 has the highest recorded value (5,767 MWh) and 12 the lowest (1 MWh). Their difference is 5,766 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
GT11Petroleum Liquids20.019.124.916.0
GT12Petroleum Liquids20.017.122.316.0
GT13Petroleum Liquids20.017.222.516.0
GT14Petroleum Liquids20.017.122.315.6
GT15Petroleum Liquids20.016.521.615.9
GT16Petroleum Liquids20.018.023.515.6
GT17Petroleum Liquids20.017.623.016.0
GT18Petroleum Liquids20.017.923.414.6
GT21Natural Gas Fired Combustion Turbine20.017.923.416.0
GT22Natural Gas Fired Combustion Turbine20.018.824.615.2
GT23Natural Gas Fired Combustion Turbine20.020.626.916.0
GT24Natural Gas Fired Combustion Turbine20.019.325.216.0
GT25Natural Gas Fired Combustion Turbine20.018.624.316.0
GT26Natural Gas Fired Combustion Turbine20.020.326.516.0
GT27Natural Gas Fired Combustion Turbine20.019.625.616.0
GT28Natural Gas Fired Combustion Turbine20.017.723.116.0
GT31Natural Gas Fired Combustion Turbine20.017.723.116.0
GT32Natural Gas Fired Combustion Turbine20.017.723.116.0
GT33Natural Gas Fired Combustion Turbine20.019.825.916.0
GT34Natural Gas Fired Combustion Turbine20.017.923.415.9
GT35Natural Gas Fired Combustion Turbine20.019.024.816.0
GT36Natural Gas Fired Combustion Turbine20.017.623.015.2
GT37Natural Gas Fired Combustion Turbine20.018.123.616.0
GT38Natural Gas Fired Combustion Turbine20.019.024.816.0
GT41Petroleum Liquids20.016.821.916.0
GT42Petroleum Liquids20.017.322.616.0
GT43Petroleum Liquids20.017.623.016.0
GT44Petroleum Liquids20.017.122.315.8
GT45Petroleum Liquids20.017.122.315.7
GT46Petroleum Liquids20.018.624.316.0
GT47Petroleum Liquids20.016.621.714.0
GT48Petroleum Liquids20.019.024.816.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check