MWPowerPlantFacts

Data last collected:

EIA plant 260

Moss Landing · Monterey · CA

Dynegy Moss Landing Power Plant Hybrid

Operated by Dynegy -Moss Landing LLC

Annual generation3,931,198 MWhSum of represented EIA-923 rows
Fuel codesMWH, NGCodes retained from EIA records
Grid contextCalifornia Independent System OperatorBalancing authority or NERC region

Published location

Where is Dynegy Moss Landing Power Plant Hybrid?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

36.804837, -121.782241

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle1,398 MW represented
TechnologyBatteries750 MW represented

Grouped from this plant’s represented generator records. Use the CA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1543,519
2389,404
3275,418
4206,557
5214,064
6258,199
7388,901
8288,571
9286,790
10303,126
11411,505
12365,144

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1543,519
2389,404
3275,418
4206,557
5214,064
6258,199
7388,901
8288,571
9286,790
10303,126
11411,505
12365,144

2024 monthly net generation

MonthNet generation
1543,519 MWh
2389,404 MWh
3275,418 MWh
4206,557 MWh
5214,064 MWh
6258,199 MWh
7388,901 MWh
8288,571 MWh
9286,790 MWh
10303,126 MWh
11411,505 MWh
12365,144 MWh

Operating generators

IDTechnologyFuelMWStatus
BAT3BatteriesMWH350OP
BAT1BatteriesMWH300OP
CT1ANatural Gas Fired Combined CycleNG233OP
CT1BNatural Gas Fired Combined CycleNG233OP
CT2ANatural Gas Fired Combined CycleNG233OP
CT2BNatural Gas Fired Combined CycleNG233OP
ST1Natural Gas Fired Combined CycleNG233OP
ST2Natural Gas Fired Combined CycleNG233OP
BAT2BatteriesMWH100OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
260
Sector
IPP Non-CHP
Water source
Moss Landing Harbor
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Dynegy Moss Landing Power Plant Hybrid power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Dynegy Moss Landing Power Plant Hybrid

Variation in the published months

Across 12 numeric monthly generation entries, 1 has the highest recorded value (543,519 MWh) and 4 the lowest (206,557 MWh). Their difference is 336,962 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 9 numeric rows displayed in this table, MW ranges from 100 (BAT2) to 350 (BAT3). The difference is 250 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
BAT1Batteries300.0300.0300.00.2
BAT2Batteries100.0100.0100.00.2
BAT3Batteries350.0350.0350.00.2
CT1ANatural Gas Fired Combined Cycle233.0165.0165.080.0
CT1BNatural Gas Fired Combined Cycle233.0165.0165.080.0
CT2ANatural Gas Fired Combined Cycle233.0165.0165.080.0
CT2BNatural Gas Fired Combined Cycle233.0165.0165.080.0
ST1Natural Gas Fired Combined Cycle233.0180.0180.060.0
ST2Natural Gas Fired Combined Cycle233.0180.0180.060.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check