EIA plant 50969

Columbia · Boone · MO

MU Combined Heat and Power Plant

Operated by Curators of the University of Missouri

Annual generation192,116 MWhSum of represented EIA-923 rows
Fuel codesNG, DFOCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is MU Combined Heat and Power Plant?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

38.946100, -92.332800

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Steam Turbine47.1 MW represented
TechnologyNatural Gas Fired Combustion Turbine34.6 MW represented
TechnologyPetroleum Liquids3 MW represented

Grouped from this plant’s represented generator records. Use the MO plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

113,083.58
215,678.1
316,668.68
415,273.24
516,887.9
616,877
719,728.46
819,510
918,155
1016,018
1111,566
1212,670

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
113,083.58
215,678.1
316,668.68
415,273.24
516,887.9
616,877
719,728.46
819,510
918,155
1016,018
1111,566
1212,670

2024 monthly net generation

MonthNet generation
113,084 MWh
215,678 MWh
316,669 MWh
415,273 MWh
516,888 MWh
616,877 MWh
719,728 MWh
819,510 MWh
918,155 MWh
1016,018 MWh
1111,566 MWh
1212,670 MWh

Operating generators

IDTechnologyFuelMWStatus
GEN3Natural Gas Steam TurbineNG19.8OP
NTG1Natural Gas Fired Combustion TurbineNG17.3OP
NTG2Natural Gas Fired Combustion TurbineNG17.3OP
GEN4Natural Gas Steam TurbineNG14.5OP
GEN2Natural Gas Steam TurbineNG12.5OP
DGT1Petroleum LiquidsDFO2SB
GEN7Petroleum LiquidsDFO1SB
6025Natural Gas Steam TurbineNG0.3OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
50969
Sector
Commercial CHP
Water source
Wells
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right MU Combined Heat and Power Plant power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at MU Combined Heat and Power Plant

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (19,728 MWh) and 11 the lowest (11,566 MWh). Their difference is 8,162 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 8 numeric rows displayed in this table, MW ranges from 0.3 (6025) to 19.8 (GEN3). The difference is 19.5 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
6025Natural Gas Steam Turbine0.30.30.30.1
DGT1Petroleum Liquids2.02.02.01.0
GEN2Natural Gas Steam Turbine12.512.212.33.0
GEN3Natural Gas Steam Turbine19.819.219.43.0
GEN4Natural Gas Steam Turbine14.513.313.43.0
GEN7Petroleum Liquids1.01.01.00.5
NTG1Natural Gas Fired Combustion Turbine17.311.414.52.0
NTG2Natural Gas Fired Combustion Turbine17.311.414.52.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.