MWPowerPlantFacts

Data last collected:

EIA plant 55220

Sallis · Attala · MS

Attala

Operated by Entergy Mississippi LLC

Annual generation2,956,937 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextMidcontinent Independent Transmission System Operator, Inc..Balancing authority or NERC region

Published location

Where is Attala?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

33.014700, -89.675300

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle551.3 MW represented

Grouped from this plant’s represented generator records. Use the MS plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1327,894
2254,140
3355,899
4321,890
652,834
7332,262
8333,573
9302,633
10358,249
1191,945
12225,618

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 11 of 11 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1327,894
2254,140
3355,899
4321,890
652,834
7332,262
8333,573
9302,633
10358,249
1191,945
12225,618

2024 monthly net generation

MonthNet generation
1327,894 MWh
2254,140 MWh
3355,899 MWh
4321,890 MWh
652,834 MWh
7332,262 MWh
8333,573 MWh
9302,633 MWh
10358,249 MWh
1191,945 MWh
12225,618 MWh

Operating generators

IDTechnologyFuelMWStatus
A03Natural Gas Fired Combined CycleNG198.1OP
A01Natural Gas Fired Combined CycleNG176.6OP
A02Natural Gas Fired Combined CycleNG176.6OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
55220
Sector
Electric Utility
Water source
Big Black River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Attala power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Attala

Variation in the published months

Across 11 numeric monthly generation entries, 10 has the highest recorded value (358,249 MWh) and 6 the lowest (52,834 MWh). Their difference is 305,415 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 176.6 (A01, A02) to 198.1 (A03). The difference is 21.5 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
A01Natural Gas Fired Combined Cycle176.6Not suppliedNot supplied95.0
A02Natural Gas Fired Combined Cycle176.6Not suppliedNot supplied95.0
A03Natural Gas Fired Combined Cycle198.1459.3515.560.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.