MWPowerPlantFacts

Data last collected:

EIA plant 55225

Broken Arrow · Wagoner · OK

Oneta Energy Center

Operated by Oneta Power LLC

Annual generation5,647,008 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextSouthwest Power PoolBalancing authority or NERC region

Published location

Where is Oneta Energy Center?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

36.011900, -95.696700

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle1,214 MW represented

Grouped from this plant’s represented generator records. Use the OK plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1447,633
2324,794
3348,319
4463,262
5555,165
6534,873
7639,616
8557,586
9492,723
10326,922
11510,226
12445,889

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1447,633
2324,794
3348,319
4463,262
5555,165
6534,873
7639,616
8557,586
9492,723
10326,922
11510,226
12445,889

2024 monthly net generation

MonthNet generation
1447,633 MWh
2324,794 MWh
3348,319 MWh
4463,262 MWh
5555,165 MWh
6534,873 MWh
7639,616 MWh
8557,586 MWh
9492,723 MWh
10326,922 MWh
11510,226 MWh
12445,889 MWh

Operating generators

IDTechnologyFuelMWStatus
STG1Natural Gas Fired Combined CycleNG255OP
STG2Natural Gas Fired Combined CycleNG255OP
CTG1Natural Gas Fired Combined CycleNG176OP
CTG2Natural Gas Fired Combined CycleNG176OP
CTG3Natural Gas Fired Combined CycleNG176OP
CTG4Natural Gas Fired Combined CycleNG176OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
55225
Sector
IPP Non-CHP
Water source
Municipality
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Oneta Energy Center power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Oneta Energy Center

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (639,616 MWh) and 2 the lowest (324,794 MWh). Their difference is 314,822 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 6 numeric rows displayed in this table, MW ranges from 176 (CTG1, CTG2, CTG3) to 255 (STG1, STG2). The difference is 79 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CTG1Natural Gas Fired Combined Cycle176.0149.3160.185.0
CTG2Natural Gas Fired Combined Cycle176.0149.3160.185.0
CTG3Natural Gas Fired Combined Cycle176.0149.3160.185.0
CTG4Natural Gas Fired Combined Cycle176.0149.3160.185.0
STG1Natural Gas Fired Combined Cycle255.0244.6243.960.0
STG2Natural Gas Fired Combined Cycle255.0244.6243.960.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check