MWPowerPlantFacts

Data last collected:

EIA plant 55970

Herald · Sacramento · CA

Cosumnes

Operated by Sacramento Municipal Util Dist

Annual generation3,841,500 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextBalancing Authority of Northern CaliforniaBalancing authority or NERC region

Published location

Where is Cosumnes?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

38.338475, -121.123978

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle556.8 MW represented

Grouped from this plant’s represented generator records. Use the CA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1406,660
2366,582.01
3380,200.01
40
5172,632
6326,662
7376,861.99
8370,000.01
9362,217
10321,458
11369,421.01
12388,806

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1406,660
2366,582.01
3380,200.01
40
5172,632
6326,662
7376,861.99
8370,000.01
9362,217
10321,458
11369,421.01
12388,806

2024 monthly net generation

MonthNet generation
1406,660 MWh
2366,582 MWh
3380,200 MWh
40 MWh
5172,632 MWh
6326,662 MWh
7376,862 MWh
8370,000 MWh
9362,217 MWh
10321,458 MWh
11369,421 MWh
12388,806 MWh

Operating generators

IDTechnologyFuelMWStatus
2Natural Gas Fired Combined CycleNG196.8OP
1Natural Gas Fired Combined CycleNG190OP
3Natural Gas Fired Combined CycleNG170OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
55970
Sector
Electric Utility
Water source
Unavailable
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Cosumnes power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Cosumnes

Variation in the published months

Across 12 numeric monthly generation entries, 1 has the highest recorded value (406,660 MWh) and 4 the lowest (0 MWh). Their difference is 406,660 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 170 (3) to 196.8 (2). The difference is 26.8 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Natural Gas Fired Combined Cycle190.0171.0178.6160.0
2Natural Gas Fired Combined Cycle196.8185.0202.0160.0
3Natural Gas Fired Combined Cycle170.0189.0201.0160.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check