EIA plant 56196

Astoria · Queens · NY

Zeltmann

Operated by New York Power Authority

Annual generation3,681,252 MWhSum of represented EIA-923 rows
Fuel codesNGCodes retained from EIA records
Grid contextNew York Independent System OperatorBalancing authority or NERC region

Published location

Where is Zeltmann?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

40.788900, -73.906900

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyNatural Gas Fired Combined Cycle528 MW represented

Grouped from this plant’s represented generator records. Use the NY plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1349,020
2344,288
3191,057
4354,976
5285,143
6339,821
7364,716
8362,473
9340,507
10175,531
11283,698
12290,022

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1349,020
2344,288
3191,057
4354,976
5285,143
6339,821
7364,716
8362,473
9340,507
10175,531
11283,698
12290,022

2024 monthly net generation

MonthNet generation
1349,020 MWh
2344,288 MWh
3191,057 MWh
4354,976 MWh
5285,143 MWh
6339,821 MWh
7364,716 MWh
8362,473 MWh
9340,507 MWh
10175,531 MWh
11283,698 MWh
12290,022 MWh

Operating generators

IDTechnologyFuelMWStatus
CA01Natural Gas Fired Combined CycleNG188OP
CT01Natural Gas Fired Combined CycleNG170OP
CT02Natural Gas Fired Combined CycleNG170OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
56196
Sector
Electric Utility
Water source
East River
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Zeltmann power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Zeltmann

Variation in the published months

Across 12 numeric monthly generation entries, 7 has the highest recorded value (364,716 MWh) and 10 the lowest (175,531 MWh). Their difference is 189,185 MWh. Missing months have not been treated as zero.

Reading the MW column

In the 3 numeric rows displayed in this table, MW ranges from 170 (CT01, CT02) to 188 (CA01). The difference is 18 in the column's stated units. This summary covers the displayed rows and retains the table's period and scope.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
CA01Natural Gas Fired Combined Cycle188.0Not suppliedNot suppliedNot supplied
CT01Natural Gas Fired Combined Cycle170.0238.0270.2135.0
CT02Natural Gas Fired Combined Cycle170.0238.0270.2135.0

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.