MWPowerPlantFacts

Data last collected:

EIA plant 6175

Pomeroy · Whitman · WA

Lower Granite

Operated by USACE Northwestern Division

Annual generation1,273,521 MWhSum of represented EIA-923 rows
Fuel codesWATCodes retained from EIA records
Grid contextBonneville Power AdministrationBalancing authority or NERC region

Published location

Where is Lower Granite?

This locator uses the coordinates in the approved source record. It shows geographic context, not a site boundary, safety zone or property-risk area.

46.659503, -117.429385

Open the interactive map ↗
Capacity is not generation. Nameplate MW describes equipment; annual MWh describes recorded output. Proposed and retired units are not added to operating capacity.

Equipment mix

Operating capacity by technology

TechnologyConventional Hydroelectric810 MW represented

Grouped from this plant’s represented generator records. Use the WA plant index for regional peers.

See the evidence

Electricity output across the year

Monthly net generation shows the seasonal shape of this plant's represented output. A negative value is retained when the source reports net consumption.

1115,773
2161,029
3192,364
471,557
578,464
6104,712
790,424
894,960
993,934
1076,806
1187,356
12106,142

MWh net generation · 2024 final edition · EIA 923 represented operating rows. 12 of 12 supplied rows shown; 0 missing values omitted. Months with no reported numeric value are omitted, not treated as zero.

Read the chart as a table
Electricity output across the year — MWh net generation
RecordMWh net generation
1115,773
2161,029
3192,364
471,557
578,464
6104,712
790,424
894,960
993,934
1076,806
1187,356
12106,142

2024 monthly net generation

MonthNet generation
1115,773 MWh
2161,029 MWh
3192,364 MWh
471,557 MWh
578,464 MWh
6104,712 MWh
790,424 MWh
894,960 MWh
993,934 MWh
1076,806 MWh
1187,356 MWh
12106,142 MWh

Operating generators

IDTechnologyFuelMWStatus
1Conventional HydroelectricWAT135OP
2Conventional HydroelectricWAT135OP
3Conventional HydroelectricWAT135OP
4Conventional HydroelectricWAT135OP
5Conventional HydroelectricWAT135OP
6Conventional HydroelectricWAT135OP

Continue exploring

Similar-capacity plants in the same state

Identity, technology and limitations
EIA plant ID
6175
Sector
Electric Utility
Water source
Snake And Columbia Rivers
Data edition
2024-final

Use this record

Questions this evidence can answer

01What exactly is this record?

Use the name, place, date and identifiers above to confirm that you have the right Lower Granite power plant: capacity and generation | PowerPlantFacts record.

02What does the evidence establish?

Read the reported values with their units, coverage dates and source notes. Keep observed facts separate from estimates or interpretation.

03What should I verify next?

Follow the primary-source links and check the limitations before using this evidence for a decision, comparison or citation.

A closer look at Lower Granite

Variation in the published months

Across 12 numeric monthly generation entries, 3 has the highest recorded value (192,364 MWh) and 4 the lowest (71,557 MWh). Their difference is 120,807 MWh. Missing months have not been treated as zero.

Generator capacity in different operating conditions

Generator IDTechnologyNameplate MWSummer MWWinter MWMinimum load MW
1Conventional Hydroelectric135.0135.0135.0110.0
2Conventional Hydroelectric135.0127.0127.046.4
3Conventional Hydroelectric135.0135.0135.046.4
4Conventional Hydroelectric135.0135.0135.057.5
5Conventional Hydroelectric135.0135.0135.057.5
6Conventional Hydroelectric135.0135.0135.057.5

EIA-860 2024 final source. Ratings describe capacity, not actual generation or availability. Missing ratings are not zero.

Source: US Energy Information Administration Form EIA-860 2024 plant and operable-generator workbooks; archive 2024. US EIA-authored information is generally public domain; cite EIA, preserve third-party exceptions, changes and no-endorsement context. Source-specific derived data.

Power plant research

Before you decide, check these points against the current source.

Things to check